2. Basic Commands
Increments Right blanking:
Command [0]
Command [1]
Data
byTypeBlanking : one byte describing the type of blanking
Data [0] = 0 : blanking on image file (saved in image file)
Data [0] = 1 : blanking on display
WStep = unsigned word representing the amount of increments
The maximum number of pixels which can be blanked depends on the native resolution of the panels

2.41.7 Blanking, Decrement

Description
Decrements the blanking value by one.
Command
Decrements Top blanking:
Command [0]
Command [1]
Decrements Bottom blanking:
Command [0]
Command [1]
Decrements Left blanking:
Command [0]
Command [1]
Decrements Right blanking:
Command [0]
Command [1]
Data
byTypeBlanking : one byte describing the type of blanking
Data [0] = 0 : blanking on image file (saved in image file)
Data [0] = 1 : blanking on display
WStep = unsigned word representing the amount of decrements
The maximum number of pixels which can be blanked depends on the native resolution of the panels

2.41.8 Minimum Blanking, Read

Description
Reads the Minimum values for the blanking.
Command
Reads minimal top blanking:
84
\x22
\x4f
\x23
\x4c
\x23
\x4d
\x23
\x4e
\x23
\x4f
R5976884 RLM SERIES 04/04/2006