HP D5970A - NetServer - LCII Installation And Configuration Manual page 87

Hp netserver ultra3 scsi hba guide
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

[xxxxx0a3] Adapter diagnostic failure - possible resource conflict
The driver failed the internal software or hardware diagnostic. Refer to your
host bus adapter User's Guide for troubleshooting information.
[xxxxx0ca] Cannot initialize device
The system, host bus adapter, or target device is busy or is not responding. The
target device could not be initialized.
[xxxxxcb] Unable to allocate memory. Decrease ad160_instr_buffersz in space.c
The driver has requested a larger buffer size than the available RAM. Either add
RAM to the system or decrease the user option ad160_inotr_buffersz in
the /etc/conf/pack.d/ad160/space.c file.
[xxxxx0cc] CONFLICT: Disconnection must be enabled in order for Tagged Queueing
to work
Use the SCSISelect utility of your host bus adapter to enable Disconnection for
each device reporting this message. Alternatively, disable Tagged Queueing in
the /etc/conf/pack.d/ad160/space.c file by setting
ad160_do_tagged=0. If Tagged Queueing is disabled, performance may be
negatively affected.
81

Advertisement

Table of Contents
loading

Table of Contents