[xxxxx099] Adapter software initialization failure
[xxxxx09a] Adapter software initialization failure
[xxxxx09b] Adapter software initialization failure
An error has occurred initializing one of the driver's internal data structures for
a device connected to the adapter. This may result in problems accessing the
device. Try installing the most up-to-date version of the driver available from
the HP Web site located at http://netserver.hp.com/netserver/
[xxxxx0ab] Driver already loaded for this host bus adapter
The driver is already loaded for this adapter. Verify that the correct adapter is
specified in your command line or startup file.
[xxxxx0ac] Driver already loaded for all host bus adapters
The driver is already loaded for all the supported adapters in this system.
[xxxxx0a4] SCSI bus reset by third party hardware
Hardware such as an array enclosure may have reset the SCSI bus. This is a
normal condition unless you receive additional errors.
[xxxxx0a7] Unable to allocate memory
[xxxxx0a8] Unable to allocate memory
This indicates that there may be a problem with the amount of memory installed
in your system. Verify that your system has at least the minimum amount of
memory required by your operating system.
[xxxxx0a9] Possible interrupt conflict
This indicates that the adapter IRQ conflicts with the IRQ of another board
installed in your system. Check your hardware documentation for instructions
on setting and changing IRQs.
[xxxxx0c9] Invalid command line parameter
A command line option for the driver is invalid. See "Using the Load Command
Line Options" on page 55 for valid command line options.