Table 19
describes the nonport side LEDs.
.
Table 19
Nonport side LED patterns during normal operation
LED name
LED color
Power Supply
No light
Status
Steady green
Steady amber (for
more than five
seconds)
Fan Status
No light
Steady green
Steady amber (for
more than five
seconds)
Status of hardware
Power supply is not receiving
power or is off.
Power supply is operating
normally.
Power supply fault for one of
the following reasons:
•
power cable is
disconnected
•
power supply is off
•
the power supply has
failed
Fan assembly is not receiving
power.
Fan assembly is operating
normally.
Fan fault for one of the
following reasons:
•
one or more of the fan(s)
in the fan assembly has
failed
•
the fan FRU was
disabled by the user
SAN Switch 2/8V, 2/16V, 2/16N and 4/32 installation guide
Recommended action
Verify that the power supply is on
and seated and the power cord is
connected to a functioning power
source.
No action required.
Try the following:
•
check the power cable
connection
•
verify that the power supply is
powered on
•
replace the power supply
No action required.
No action required.
Verify that the fan FRU is enabled. If
the fan FRU is enabled, the FRU is
faulty and should be replaced.
75