Table 26
General specifications (continued)
Specification
EMC immunity
System architecture
System processor for the
2/8V, 2/16V and 2/16N
System processor for the 4/32 PowerPC 440GP, 400 MHz CPU
ANSI Fibre Channel protocol
Modes of operation for the
2/8V, 2/16V and 2/16N
Modes of operation for the
4/32
Fabric initialization for the
2/8V, 2/16V and 2/16N
Fabric initialization for the
4/32
FC–IP (IP over Fibre Channel)
Aggregate switch I/O
bandwidth for the 2/8V,
2/16V and 2/16N
Description
•
IEC 61000–4–2 Severity Level 3 for Electrostatic Discharge
•
IEC 61000–4–3 Severity Level 3 for Radiated Fields
•
IEC 61000–4–4 Severity Level 3 for Fast Transients
•
IEC 61000–4–5 Severity Level 3 for Surge Voltage
•
IEC 61000–4–6 Conducted Emissions
•
IEC 61000–4–11 Voltage Variations
•
EN 61000–4–12 Oscillatory Waves Immunity
•
EN 61000–3–2 Limits for Harmonic Current Emissions
•
EN 61000–3–3 JEIDA
Nonblocking shared-memory switch
PPC405GP, 200 MHz CPU
FC–PH (Fibre Channel Physical and Signalling Interface standard)
Fibre Channel Class 2, Class 3 and Class F
Fibre Channel Class 2 and Class 3
Complies with FC–SW 5.0
Complies with FC–SW–3 Rev. 6.6
Complies with FC–IP 2.3 of FCA profile
64 Gb/s if all 16 ports are running at 2Gb/s, full duplex
SAN Switch 2/8V, 2/16V, 2/16N and 4/32 installation guide
101