Led Patterns; Module Status Led Patterns; Module Status Led Patterns During Normal Operation - HP StorageWorks Brocade User Manual

Switch for hp c-class bladesystem
Hide thumbs Also See for StorageWorks Brocade:
Table of Contents

Advertisement

LED patterns

Table 12
recommended user response.

Module status LED patterns

The system and power LED patterns are shown in
Table 12 Module Status LED patterns during normal operation
LED name, location LED color
Module Status LED
and
Table 13
summarize LED location, color, and meaning, as well as any
No light
Steady green
Flashing green (on
1 second, off 1
second)
Amber
Table
Status of hardware Recommended
Switch is off, boot
is not complete, or
boot failed.
Switch is on and
functioning.
One or both of the
following are true:
One or more
environmental
ranges are
exceeded.
Error log contains
one or more port
diagnostic error
messages.
Boot-up state, one or
more ports offline.
Brocade 4Gb SAN Switch for HP c-Class BladeSystem
12.
action
Verify that switch is
on and completed
booting.
No action required.
Check environmental
conditions, error log,
Port Status LEDs,
transceivers, cables,
and loopback
plugs. Correct error
condition. Clear
error log. Rerun
diagnostics to verify
fix.
Needs attention.