Environmental requirements
To ensure proper operation, the switch must not be subjected to environmental conditions
beyond those for which it was tested. The ranges specified in
environment for both operating and non-operating conditions.
Table 29
Environmental requirements
Condition
Ambent
Temperature
Humidity
Altitude
Shock
Vibration
Air flow
NOTE:
The -10°- 40° Celsius range applies to the ambient air temperature at the air intake
vents on the nonport side of the switch. The temperature inside the switch can be up to 75°
Celsius during switch operation.
If the internal temperature range exceeds the operating ranges of the components, the LEDs,
error messages, and Fabric Watch alerts will indicate a problem. Enter the tempshow
commands to view temperature status.
104
SAN Switch technical specifications
Acceptable range during operation
-10× to +40× C (12× to 122× F)
20% to 85% RH non-condensing, at
40×C, with maximum gradient of
10% per hour
0 to 10,000 ft (3 km) above sea level
20 G, 6 ms duration, half sine wave
0.5 G, 5-500 Hz
24 cubic ft/minute
Table 29
list the acceptable
Acceptable range during
non-operation
-50× to 100× C (-122× to 212×
F)
10% to 85% RH noncondensing,
at 70° C
0 to 39,370 ft (12 km) above
sea level
15 G, 12-18 ms duration,
trapezoid
2.0 G, 5-500 Hz
None required