HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual page 50

Hp storageworks fabric os 6.1.1 administrator guide (5697-0235, december 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

2.
Issue the switchStatusPolicyShow command.
Whenever there is a switch change, an error message is logged and an SNMP connUnitStatusChange
trap is sent.
The output is similar to the following:
switch:admin> switchstatuspolicyshow
The current overall switch status policy parameters:
----------------------------------
PowerSupplies
Temperatures
MarginalPorts
FaultyPorts
MissingSFPs
To set the switch status policy threshold values:
1.
Connect to the switch and log in using an account assigned to the admin role.
2.
Issue the switchStatusPolicySet command.
The current switch status policy parameter values are displayed. You are prompted to enter values for
each DOWN and MARGINAL threshold parameter.
By setting the DOWN and MARGINAL values for a parameter to 0,0 that parameter is no longer used
in setting the overall status for the switch.
3.
Verify the threshold settings you have configured for each parameter.
4.
Issue the switchStatusPolicyShow command to view your current switch status policy
configuration.