Setting Up Ti Over Fcr (Sample Procedure) - HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual

Hp storageworks fabric os 6.1.1 administrator guide (5697-0235, december 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

To display information about TI zones:
Connect to the switch and log in as admin.
1.
2.
Issue the zone
zone --show [ name ]
where: name is the name of the zone to be displayed. If the name is omitted, the command displays
information about all TI zones in the defined configuration.
To display information about the TI zone redzone:
zone --show redzone
Zone Name: redzone:
List of port: 1,2; 1,3; 3,3; 4,5
Failover: Enabled
Status: Activated
To display information about all TI zones:
zone --show
Zone Name: greenzone:
List of port: 2,2; 3,3; 5,3; 4,11;
Failover: Enabled
Status: Activated
Zone Name: purplezone:
List of port: 1,2; 1,3; 3,3; 4,5;
Failover: Enabled
Status: Activated
Zone Name: bluezone:
List of port: 9,2; 9,3; 8,3; 8,5;
Failover: Disabled
Status: Deactivated

Setting up TI over FCR (sample procedure)

The following example shows how to set up TI zones over FCR to provide a dedicated path shown in
Figure
34. In this example, three TI zones are created: one in each of the edge fabrics and one in the
backbone fabric. The combination of these three TI zones creates a dedicated path for traffic between Host
1 in edge fabric 1 and Targets 1 and 2 in edge fabric 2.
Host 1 has port WWN 10:00:00:00:00:08:00:00
Target 1 has port WWN 10:00:00:00:00:02:00:00
Target 2 has port WWN 10:00:00:00:00:03:00:00
302 Optimizing fabric behavior
show command.
--