Perform the following procedure to configure and enable FC Fastwrite.
Create a zone configuration to filter FC Fastwrite flows. FC Fastwrite flows are configured by creating a
1.
zone name with an fcacc token as a prefix. For LSAN configuration, use lsan_fcacc as a prefix, as
shown in the following example:
#zonecreate fcacc_myzone1, "initiator-wwn; target-wwn"
#zonecreate LSAN_fcacc_myzone2, "initiator-wwn; target1-wwn; target2-wwn"
#cfgcreate mycfg, "fcacc_myzone1; LSAN_fcacc_myzone2"
#cfgenable mycfg
2.
Enable FC Fastwrite by issuing the fastWriteCfg command. Enabling or disabling FC Fastwrite with
this command disrupts data traffic. For the FR4- 1 8i blade, the command powers the blade off and back
on. In the case of the 400 Multi-Protocol Router, the router is rebooted. The process takes up to five
minutes.
switch:admin> fastwritecfg --enable slot
where slot is the slot number in which the FR4- 1 8i blade is installed. A slot number is not required for
the 400 Multi-Protocol Router.
Example of enabling fastwrite on a switch:
switch:admin> fastwritecfg --enable 7
!!!! WARNING !!!!
Enabling FC Fastwrite will require powering off and back on the and it may take up
to 5 minutes. For non bladed system, the switch will be rebooted. Data traffic
will be disrupted.
Continue
switch:admin> fastwritecfg --disable 7
!!!! WARNING !!!!
Disabling FC Fastwrite will require powering off and back on the and it may take
up to 5 minutes. For non bladed system, the switch will be rebooted. Data traffic
will be disrupted.
Continue
Slot 7 is being powered off
3.
Enable FC Fastwrite on the ports by issuing the portCfg command:
switch:admin> portcfg fastwrite [slot/]port --enable
where slot is the slot in which the FR4- 1 8i is installed and port identifies the port number you want to
enable. A slot number is not required for the 400 Multi-Protocol Router.
4.
Repeat
step 1
through
(Y,y,N,n): [ n]
(Y,y,N,n): [ n]
step 3
for the blade or router on the other end of the FC Fastwrite path.
y
y