Enabling And Disabling Isl Trunking - HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual

Hp storageworks fabric os 6.1.1 administrator guide (5697-0235, december 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

The following example shows traffic flowing through a trunking group (ports 5, 6, and 7). After port 6 fails,
traffic is redistributed over the remaining two links in the group, ports 5 and 7:
switch:admin> portperfshow
0
1
--------------------------------------------------------------------
0
0
0
0
0
0

Enabling and disabling ISL Trunking

You can enable or disable ISL Trunking for a single port or for an entire switch.When you execute the
commands portCfgTrunkPort or switchCfgTrunk to update the trunking configuration, the ports
for which the configuration applies are disabled and re-enabled with the new trunk configuration. As a
result, traffic through those ports could be disrupted.
IMPORTANT:
is, in a given trunk group, if there are some ports with QoS enabled and some with QoS disabled, they
would form two different trunks, one with QoS enabled and the other with QoS disabled. For more
information, see
To enable or disable ISL Trunking on one port:
1.
Connect to the switch and log in as admin.
Issue the portCfgTrunkPort command:
2.
portcfgtrunkport [slotnumber/]portnumber mode
where:
• slotnumber specifies the number of the slot in which the port blade containing the port is located.
This operand is required only for Directors.
• portnumber specifies the number of the port on which you want to enable or disable trunking.
• mode enables (1) or disables (0) trunking on the specified port.
The following example enables trunking on slot 1, port 3:
switch:admin> portcfgtrunkport 1/3 1
done.
switch:admin>
To enable or disable ISL Trunking for all of the ports on a switch:
1.
Connect to the switch and log in as admin.
2.
Issue the switchCfgTrunk command. The format is:
switchcfgtrunk mode
Mode 1 enables and mode 0 disables ISL Trunking for all ports on the switch.
The following example enables trunking all ports in the switch:
switch:admin> switchcfgtrunk 1
Committing configuration...done.
switch:admin>
2
3
4567 Total
0
0
0145m144m145m
0
0
0144m143m144m 431
0
0
0162m0162m
Trunking is performed based on QoS configuration on the master and the slave ports. That