Click Login Scripts.
2.
In the Default Login Timeout field, enter the number of seconds the Serial Session Viewer waits for a
3.
valid response to automatic login information, in the range 1 to 99999. The default value is 30
seconds.
In the Initial character dropdown list, select: CR (carriage return), CR+LF (carriage return and
4.
linefeed), CR+CR (carriage return and carriage return), ESC (Escape), CTRL+P (Control+P sequence,
0x10 in hex), or None (no initial transmission character). The default value is None.
In the first Expect field, enter the 1 to 32 alphanumeric character string that you expect from the unit.
5.
Spaces are allowed. The Manage Console Switch Default Values lists the serial console switch
default values.
In the first Send field, enter the 0 to 32 alphanumeric character string to be sent in response to the
6.
Expect string. Spaces are allowed, and a blank field is valid. A CR or CR+LF is appended to the
string, based on the New Line Mode - Outbound setting. If a Send field contains an entry, the Expect
field cannot be blank. The Manage Console Switch Default Values lists the serial console switch
default values.
You can use the following macros in the field. The HP IP Console Viewer automatically replaces
these variables when the login script runs.
Macro are replaced with:
%U user name
o