Summary of Contents for Intel SBXD62 - Server Compute Blade
Page 1
Intel® Server Compute Blade SBXD62 Installation and User’s Guide ® A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number D50275-002...
Page 2
Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
Installing the Blade Server Bezel Assembly ................31 Closing the Blade Server Cover ....................31 Installing the Blade Server in an Intel® Blade Server Chassis SBCE ........32 Updating the Blade Server Configuration ................. 33 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 4
Diagnosing Problems Using Light Path Diagnostics ..............51 Light Path Diagnostics LEDs ....................51 A Warranty ........................55 Limited Warranty for Intel® Chassis Subassembly Products ..........55 Extent of Limited Warranty ....................55 Warranty Limitations and Exclusions .................. 56 Limitations of Liability ....................... 56 How to Obtain Warranty Service ....................
Page 5
Advertencias y precauciones sobre seguridad ................. 82 Aplicaciones y usos previstos ....................83 Selección de la ubicación ......................83 Manipulación del equipo ......................83 Advertencias el acceso al sistema .................... 85 Descarga electrostática (ESD) ....................86 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 6
In Asia-Pacific region ........................ 94 Japan ............................94 Latin America ..........................94 E Installation/Assembly Safety Instructions ............97 English ..........................97 Deutsch ..........................99 Français ..........................102 Español ..........................104 Italiano ..........................106 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 7
Table 2. System Board LEDs ....................13 Table 3. Light Path Diagnostics Panel LEDs................13 Table 4. POST Beep Code Descriptions.................. 44 Table 5. Abbreviated List of POST Error Messages ..............45 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 8
Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information at http:// support.intel.com/support/motherboards/server/sb/cs-010770.htm. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen.
Reinstalling enclosure cover: For proper cooling and airflow, always install the enclosure cover before turning on the storage system. Operating it without the enclosure cover in place can damage system parts. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Note: The model number and serial number are on the ID label that is behind the control panel door on the front of the blade server, and on a label on the side of the blade server that is visible when the blade server is not in the Intel® Blade Server Chassis SBCE. ®...
• Attention: These notices indicate possible damage to programs, devices, or data. An attention notice is placed just before the instruction or situation in which damage could occur. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Server Compute Blade SBXD62 Specifications The following table is a summary of the features and specifications of the blade server. Note: Power, cooling, removable-media drives, external ports, and advanced system management are provided by the Intel® Blade Server Chassis SBCE. Microprocessor: Integrated functions:...
Intel® Blade Server Chassis SBCE. This policy is enforced when the initial power is applied to the Intel® Blade Server Chassis SBCE or when a blade server is inserted into the Intel® Blade Server Chassis SBCE. You can configure and monitor the power environment by using the management module.
Service processor that communicates with the management module to enable remote blade server management • SDRAM with serial presence detect (SPD) and vital product data (VPD) • System error logging • Wake on LAN capability Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Major Components of the Blade Server You must remove the blade server from the Intel® Blade Server Chassis SBCE and remove the cover to see the components. The following illustration shows the major ® components of the Intel Server Compute Blade SBXD62.
Web interface. Turning off the Blade Server When you turn off the blade server, it is still connected to power through the Intel® Blade Server Chassis SBCE. The blade server can respond to requests from the service processor, such as a remote request to turn on the blade server. To remove all power from the blade server, you must remove it from the Intel®...
Keyboard/video/mouse (KVM) select button: Press this button to associate the shared Intel® Blade Server Chassis SBCE keyboard port, video port, and mouse port with the blade server. The LED on this button flashes while the request is being processed then is lit when the ownership of the keyboard, video, and mouse has been transferred to the blade server.
Page 19
Although the keyboard that is attached to the Intel® Blade Server Chassis SBCE might be a PS/2 style keyboard, internal communication with it is through the USB. The operating system in the blade server must provide USB support for the blade server to recognize and use the keyboard and mouse.
DIMM 2 DIMM 3 DIMM 4 Microprocessor 1 and heat sink Microprocessor 2 and heat sink option Control-panel connector Battery SAS hard disk drive 0 SAS hard disk drive 1 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Using Light Path Diagnostics to Troubleshoot the System Board You have to remove the blade server from the Intel® Blade Server Chassis SBCE, open the cover, and press the light path diagnostics switch (SW4) to light any error LEDs that were turned on during processing.
Restart the blade server. If the error still exists, call for service. TEMP (over temperature) Check the Intel® Blade Server Chassis SBCE blowers for correct operation and the air inlets for obstructions. Make sure that the temperature of the room where the blade server is installed is within the limits specified by the “Intel®...
Page 24
Light path diagnostics button Press SW4 to find faults on the system board. If the microprocessor (SW4) or memory LED is lit, reseat the component. If the LED remains lit, replace the defective component. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Back up all important data before you make changes to disk drives. • Before you remove a hot-swap blade server from the Intel® Blade Server Chassis SBCE, you must shut down the operating system and turn off the blade server. You do not have to shut down the Intel®...
While the device is still in its static-protective package, touch it to an unpainted metal part of the Intel® Blade Server Chassis SBCE or any unpainted metal surface on any other grounded rack component in the rack you are installing the device in for at least 2 seconds.
Removing the Blade Server from an Intel® Blade Server Chassis SBCE The following illustration shows how to remove the blade server from a typical Intel® Blade Server Chassis SBCE. AF000440 Important: • To maintain proper system cooling, do not operate the Intel® Blade Server Chassis SBCE without a blade server, or filler blade installed in each blade bay.
65 in Appendix C, “Safety Information” “Installation Guidelines” on page 2. If the blade server is installed in a Intel® Blade Server Chassis SBCE, remove it (see “Removing the Blade Server from an Intel® Blade Server Chassis SBCE” on page 17 for instructions).
(RAID) level-1. See “Configuring a SCSI RAID Array” on page 42 for information about SCSI RAID configuration. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 30
2. Shut down the operating system, turn off the blade server, and remove the blade server from the Intel® Blade Server Chassis SBCE. See “Removing the Blade Server from an Intel® Blade Server Chassis SBCE” on page 17 for instructions. 3. Carefully lay the blade server on a flat, non-conductive surface.
2. Shutdown the operating system, turn off the blade server, and remove the blade server from the Intel® Blade Server Chassis SBCE. See “Removing the Blade Server from an Intel® Blade Server Chassis SBCE” on page 17 for instructions. 3. Carefully lay the blade server on a flat, non-conductive surface.
Page 32
7. Touch the static-protective package that contains the DIMM option to any unpainted metal surface on the Intel® Blade Server Chassis SBCE or any unpainted metal surface on any other grounded rack component in the rack you are installing the DIMM option in for at least 2 seconds;...
When only a single microprocessor is to be installed, it must be installed in the microprocessor 1 socket (U66). ® • For a list of processors that are supported by your blade server, see the Intel Server Compute Blade SBXD62 Supported Processor List located on http:// support.intel.com).
Page 34
2. Shut down the operating system, turn off the blade server, and remove the blade server from the Intel® Blade Server Chassis SBCE. See “Removing the Blade Server from an Intel® Blade Server Chassis SBCE” on page 17 for instructions. 3. Carefully lay the blade server on a flat, static-protective surface.
Page 35
— Do not use excessive force when pressing the microprocessor into the socket. — Make sure that the microprocessor is oriented and aligned correctly in the socket before you try to close the lever. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 36
11.15 inch-pounds). Refer to the following illustration for recommended order to tighten screws. REPEAT SEQUENCE UNTIL TIGHT. 720˚ 720˚ AF000637 4. If you have other options to install or remove, do so now; otherwise, go to “Completing the Installation” on page Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
I/O-module bays 3 and 4 on the Intel® Blade Server Chassis SBCE. For example, if you add an Ethernet expansion card to a blade server installed in a Intel® Blade Server Chassis SBCE, the I/O-modules in I/O-module bays 3 and 4 must both be compatible with the expansion card.
If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery contains lithium and can explode if not properly used, handled, or disposed of. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 39
“Installation Guidelines” on page 2. Follow any special handling and installation instructions that come with the battery. 3. Turn off the blade server and remove it from the Intel® Blade Server Chassis SBCE (see “Installing the Blade Server in an Intel® Blade Server Chassis SBCE” on page 32 for instructions).
Important: Hazardous energy is present when the blade server is connected to the power source. Always replace the blade cover before installing the blade server. 4. Reinsert the blade server into the bay in the Intel® Blade Server Chassis SBCE. 5. Turn on the blade server.
3. Carefully slide the bezel assembly onto the blade server until it clicks into place. Closing the Blade Server Cover Important: The blade server cannot be inserted into the Intel® Blade Server Chassis SBCE until the cover is installed and closed or an expansion unit is installed. Do not attempt to override this protection.
If the blade server has an expansion unit installed on it, the blade server and expansion option require two adjacent bays. b. When any blade server or option is in blade bay 7 through 14 in a Intel® Blade Server Chassis SBCE, power modules must be present in all four power-module bays.
If this is the initial installation for the blade server in the Intel® Blade Server Chassis SBCE, you must configure the blade server through the Configuration/Setup Utility program and install the blade server operating system.
Input/Output Connectors and Devices The input/output connectors that are available to the blade server are supplied by the Intel® Blade Server Chassis SBCE. See the documentation that comes with the Intel® Blade Server Chassis SBCE for information about the input/output connectors.
“Understanding the Control Panel and LEDs” on page 8 for information). — If you are managing the blade server from a remote location, see the Intel® Server Management Module SBCECMM User’s Guide, Intel® Management Module Command-Line Interface Reference Guide, or Serial over LAN (SOL) Setup Guide for information and instructions.
Select this choice to view information about the integrated video controller. — System MAC Addresses Select this choice to set and view the MAC addresses for the Ethernet controllers on the blade server. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 47
Hot Spare Memory pair of DIMMs to replace the failed memory pair of DIMMs. Before you can enable the memory mirroring or sparing, at least two pairs of DIMMs must be installed in the blade server that adhere to the Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 48
Select this choice to exit from the Configuration/Setup Utility program. If you have not saved the changes you have made in the settings, you are asked whether you want to save the changes or exit without saving them. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
2. Note: Shut down the operating system, turn off the blade server, and remove the blade server from the Intel® Blade Server Chassis SBCE to access the switches. Using the PXE Boot Agent Utility Program Use the Preboot Execution Environment (PXE) boot agent utility program to select the boot protocol and other boot options and to select a power-management option.
Firmware updates Intel will periodically make firmware updates available for the blade server. Use the following table to determine the methods that you can use to install these firmware updates. Important: To avoid problems and to maintain proper system performance, always make sure that the BIOS, service processor (BMC), and diagnostic firmware levels are consistent for all blade servers within the Intel®...
Important: To support failover on the blade server Ethernet controllers, the Ethernet switch modules in the Intel® Blade Server Chassis SBCE must have identical configurations. Blade Server Ethernet Controller Enumeration The enumeration of the Ethernet controllers in a blade server is operating-system dependent.
I/O-module bays 3 and 4, if these bays are supported by your Intel® Blade Server Chassis SBCE. You can verify which controller on the card is routed to which I/O-module bay by performing the same test and using a controller on the expansion card and a compatible switch module or pass-thru module in I/O-module bay 3 or 4.
• Diagnostic programs and error messages Real Time Diagnostics tests the major components of the Intel® Blade Server Chassis SBCE, including the management modules, I/O-modules, removable media drives, and the blade servers, while the operating system is running.
POST. See “Diagnostics” in the Intel Server Compute Blade SBXD62 Hardware ® Maintenance Manual and Troubleshooting Guide on the Intel Server Compute Blade SBXD62 Resource CD for more information about POST error messages. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Have the system board serviced. checking hardware test. 012980xx Data for processor x Download and install the latest level of BIOS code. 012981xx 01298200 Microprocessor speed mismatch Install microprocessors with identical speeds. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Install an operating system. system. Troubleshooting Charts ® The following tables list problem symptoms and suggested solutions. See the Intel Server Compute Blade SBXD62 Hardware Maintenance Manual and Troubleshooting ® Guide on the Intel Server Compute Blade SBXD62 Resource CD for more detailed troubleshooting charts.
If the problem remains, call for service. Only the cursor appears. Make sure that the keyboard, video, and mouse on the Intel® Blade Server Chassis SBCE have not been switched to another blade server. If the problem remains, call for service.
Make sure that the mouse is recognized as a USB device, not PS/2, by the blade server. Although the mouse might be a PS/2-style device, communication with the mouse is through an internal USB bus in the Intel® Blade Server Chassis SBCE. Some operating systems enable you to select the type of mouse during installation of the operating system.
• The I/O-modules for the network interface that you are using are installed in communicate with the the correct bays and are configured and operating correctly. See the Intel® network. Blade Server Chassis SBCE Hardware Maintenance Manual and Troubleshooting Guide on the Resource CD that came with your Intel®...
The blade server does not Make sure that: turn on. a. The power LED on the front of the Intel® Blade Server Chassis SBCE is lit. b. The LEDs on all the power modules are lit. c. If the blade server or attached storage expansion unit is in blade bays 7 through 14 (in the Intel®...
Light Path Diagnostics If the system-error LED on the system LED panel on the front or rear of the Intel® Blade Server Chassis SBCE is lit, one or more error LEDs on the components also might be lit. These LEDs help identify the cause of the problem.
Page 62
Power is available to relight the light path diagnostics LEDs for a small period of time after the blade server is removed from the Intel® Blade Server Chassis SBCE. During that period of time, you can relight the light path diagnostics LEDs for a maximum of 25 seconds (or less, depending on the number of LEDs that are lit and the length of time the blade server is removed from the chassis) by pressing the light path diagnostics button.
Page 63
Make sure that microprocessors 1 and 2 have the mismatch (MIS) same cache size and type and the same clock speed. Internal and external clock frequencies must be identical. If the problem remains, have the blade server serviced. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 64
Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
“as is” unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
Page 68
Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
CB Certificate & Report, IEC6095-1 (report to include all country national deviations) • GOST R 50377-92 - License (Russia) • CE - Low Voltage Directive 73/23/EEE (Europe) • CNS 14336 BSMI Certification (Taiwan) Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Product EMC Compliance - Class A Compliance This blade server has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed in a compatible Intel® host system. For information on compatible host system(s) contact your local Intel representative. •...
EMC Marking (Class A) Canada VCCI Marking (Class A) Japan BSMI Certification Taiwan Number & Class A Warning GOST R Marking Russia RRL MIC Mark Korea See the regulatory information document for additional information. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
All cables used to connect to peripherals must be shielded and grounded. Operation with cables, connected to peripherals, that are not shielded and grounded may result in interference to radio and TV reception. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Install and use the equipment according to the instruction manual. BSMI (Taiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
5. Manufacturer/Nation: Intel Corporation/Refer to country of origin marked on product Restriction of Hazardous Substances (RoHS) Compliance Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration that materials banned in the RoHS Directive are either (1) below all applicable substance threshold limits or (2) an approved/pending RoHS exemption applies.
Indicates hot components or surfaces. Indicates do not touch fan blades, may result in injury. Indicates to unplug all AC power cord(s) to disconnect AC power Please recycle battery Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Turn off all peripheral devices connected to this product. • Turn off the system by pressing the power button to off. • Disconnect the AC power by unplugging all AC power cords from the system or wall outlet. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, bevor Sie Ihr Intel®...
Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 82
Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
Einbauen von Hot-Plug-Komponenten sorgfältig vor, um nicht mit heißen Komponenten in Berührung zu kommen. Vorsicht: Berühren Sie nicht die rotierenden Lüfterflügel, um Verletzungen zu vermeiden. Falls Ihr System mit eine Lüfterabdeckung besitzt, darf es nicht ohne diese Abdeckung betrieben werden. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant...
• Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 88
Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
Page 89
Attention: Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre système est fourni avec une protection sur le ventilateur, ne mettez pas le système en route sans la protection en place. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Utilisez si possible un tapi de mousse conducteru, mais pas l’emballage de la carte. Veillez à ce que la carte ne glisse sur aucune surface. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au fabricant en cas de problème. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , los gabinetes de servidor de ® Intel (montaje en rack y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y...
Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 94
CA estén desenchufado antes de abrir le gabinete, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques eléctricos use precauciones al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Utilice una almohadilla de espuma conductora si dispone de ella, pero nunca el envoltorio de la tarjeta. No deslice la tarjeta sobre ninguna superficie. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 97
• No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). For an updated support contact list, see http://www.intel.com/support/9089.htm/...
Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 105
Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 106
Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
1. Unlock and remove the padlock from the back of the system if a padlock has been installed. 2. Remove and save all screws from the covers. 3. Remove the cover(s). Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 108
• Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 110
Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 111
Telekommunikationsleitungen mit dem Modem bestehen; • "mit einer geerdeten Wechselstromsteckdose ausgerüstet sein; • "über ausreichend Platz verfügen, um Zugang zu den Netzkabeln zu gewährleisten, da der Stromanschluß des Produkts hauptsächlich über die Kabel unterbrochen wird Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
1. Si un cadenas a été installé sur à l'arrière du système, déverrouillez-le et retirez-le. 2. Retirez toutes les vis des panneaux et mettez-les dans un endroit sûr. 3. Retirez les panneaux. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 113
• "Muni d'une prise murale correctement mise à la terre. • "Suffisamment spacieux pour vous permettre d'accéder aux câbles d'alimentation (ceux-ci étant le seul moyen de mettre le système hors tension). Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos de las tapas.Extraiga las tapas. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 115
"Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 117
• "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
Page 118
Intel® Server Compute Blade SBXD62 Installation and User’s Guide...