Intel SBXD62 - Server Compute Blade Installation And User Manual
Intel SBXD62 - Server Compute Blade Installation And User Manual

Intel SBXD62 - Server Compute Blade Installation And User Manual

Server compute blade
Table of Contents

Advertisement

Quick Links

Intel® Server Compute Blade SBXD62
Installation and User's Guide
®
A Guide for Technically Qualified Assemblers of Intel
Identified Subassemblies/
Products
Intel Order Number D50275-002

Advertisement

Table of Contents
loading

Summary of Contents for Intel SBXD62 - Server Compute Blade

  • Page 1 Intel® Server Compute Blade SBXD62 Installation and User’s Guide ® A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number D50275-002...
  • Page 2 Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
  • Page 3: Table Of Contents

    Installing the Blade Server Bezel Assembly ................31 Closing the Blade Server Cover ....................31 Installing the Blade Server in an Intel® Blade Server Chassis SBCE ........32 Updating the Blade Server Configuration ................. 33 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 4 Diagnosing Problems Using Light Path Diagnostics ..............51 Light Path Diagnostics LEDs ....................51 A Warranty ........................55 Limited Warranty for Intel® Chassis Subassembly Products ..........55 Extent of Limited Warranty ....................55 Warranty Limitations and Exclusions .................. 56 Limitations of Liability ....................... 56 How to Obtain Warranty Service ....................
  • Page 5 Advertencias y precauciones sobre seguridad ................. 82 Aplicaciones y usos previstos ....................83 Selección de la ubicación ......................83 Manipulación del equipo ......................83 Advertencias el acceso al sistema .................... 85 Descarga electrostática (ESD) ....................86 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 6 In Asia-Pacific region ........................ 94 Japan ............................94 Latin America ..........................94 E Installation/Assembly Safety Instructions ............97 English ..........................97 Deutsch ..........................99 Français ..........................102 Español ..........................104 Italiano ..........................106 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 7 Table 2. System Board LEDs ....................13 Table 3. Light Path Diagnostics Panel LEDs................13 Table 4. POST Beep Code Descriptions.................. 44 Table 5. Abbreviated List of POST Error Messages ..............45 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 8 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 9: Safety Information

    Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information at http:// support.intel.com/support/motherboards/server/sb/cs-010770.htm. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen.
  • Page 10: Warnings

    Reinstalling enclosure cover: For proper cooling and airflow, always install the enclosure cover before turning on the storage system. Operating it without the enclosure cover in place can damage system parts. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 11: Introduction

    Note: The model number and serial number are on the ID label that is behind the control panel door on the front of the blade server, and on a label on the side of the blade server that is visible when the blade server is not in the Intel® Blade Server Chassis SBCE. ®...
  • Page 12: Related Documentation

    • Attention: These notices indicate possible damage to programs, devices, or data. An attention notice is placed just before the instruction or situation in which damage could occur. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 13: Intel ® Server Compute Blade Sbxd62 Specifications

    Server Compute Blade SBXD62 Specifications The following table is a summary of the features and specifications of the blade server. Note: Power, cooling, removable-media drives, external ports, and advanced system management are provided by the Intel® Blade Server Chassis SBCE. Microprocessor: Integrated functions:...
  • Page 14: Intel ® Server Compute Blade Sbxd62 Features

    Intel® Blade Server Chassis SBCE. This policy is enforced when the initial power is applied to the Intel® Blade Server Chassis SBCE or when a blade server is inserted into the Intel® Blade Server Chassis SBCE. You can configure and monitor the power environment by using the management module.
  • Page 15: Reliability, Availability, And Serviceability Features

    Service processor that communicates with the management module to enable remote blade server management • SDRAM with serial presence detect (SPD) and vital product data (VPD) • System error logging • Wake on LAN capability Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 16: Major Components Of The Blade Server

    Major Components of the Blade Server You must remove the blade server from the Intel® Blade Server Chassis SBCE and remove the cover to see the components. The following illustration shows the major ® components of the Intel Server Compute Blade SBXD62.
  • Page 17: Power, Controls, Jumpers, Switches, And Indicators

    Web interface. Turning off the Blade Server When you turn off the blade server, it is still connected to power through the Intel® Blade Server Chassis SBCE. The blade server can respond to requests from the service processor, such as a remote request to turn on the blade server. To remove all power from the blade server, you must remove it from the Intel®...
  • Page 18: Understanding The Control Panel And Leds

    Keyboard/video/mouse (KVM) select button: Press this button to associate the shared Intel® Blade Server Chassis SBCE keyboard port, video port, and mouse port with the blade server. The LED on this button flashes while the request is being processed then is lit when the ownership of the keyboard, video, and mouse has been transferred to the blade server.
  • Page 19 Although the keyboard that is attached to the Intel® Blade Server Chassis SBCE might be a PS/2 style keyboard, internal communication with it is through the USB. The operating system in the blade server must provide USB support for the blade server to recognize and use the keyboard and mouse.
  • Page 20: System Board Illustration

    DIMM 2 DIMM 3 DIMM 4 Microprocessor 1 and heat sink Microprocessor 2 and heat sink option Control-panel connector Battery SAS hard disk drive 0 SAS hard disk drive 1 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 21: Using System Board Switches

    6 - Clear CMOS – Off: Disabled – On: Enabled • 7 - Reserved • 8 - Bypass power-on password during next server start – Off: Disabled (default) – On: Enabled Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 22: Using Light Path Diagnostics To Troubleshoot The System Board

    Using Light Path Diagnostics to Troubleshoot the System Board You have to remove the blade server from the Intel® Blade Server Chassis SBCE, open the cover, and press the light path diagnostics switch (SW4) to light any error LEDs that were turned on during processing.
  • Page 23: Table 2. System Board Leds

    Restart the blade server. If the error still exists, call for service. TEMP (over temperature) Check the Intel® Blade Server Chassis SBCE blowers for correct operation and the air inlets for obstructions. Make sure that the temperature of the room where the blade server is installed is within the limits specified by the “Intel®...
  • Page 24 Light path diagnostics button Press SW4 to find faults on the system board. If the microprocessor (SW4) or memory LED is lit, reseat the component. If the LED remains lit, replace the defective component. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 25: Installing Options

    Back up all important data before you make changes to disk drives. • Before you remove a hot-swap blade server from the Intel® Blade Server Chassis SBCE, you must shut down the operating system and turn off the blade server. You do not have to shut down the Intel®...
  • Page 26: Handling Static-Sensitive Devices

    While the device is still in its static-protective package, touch it to an unpainted metal part of the Intel® Blade Server Chassis SBCE or any unpainted metal surface on any other grounded rack component in the rack you are installing the device in for at least 2 seconds.
  • Page 27: Removing The Blade Server From An Intel® Blade Server Chassis Sbce

    Removing the Blade Server from an Intel® Blade Server Chassis SBCE The following illustration shows how to remove the blade server from a typical Intel® Blade Server Chassis SBCE. AF000440 Important: • To maintain proper system cooling, do not operate the Intel® Blade Server Chassis SBCE without a blade server, or filler blade installed in each blade bay.
  • Page 28: Opening The Blade Server Cover

    65 in Appendix C, “Safety Information” “Installation Guidelines” on page 2. If the blade server is installed in a Intel® Blade Server Chassis SBCE, remove it (see “Removing the Blade Server from an Intel® Blade Server Chassis SBCE” on page 17 for instructions).
  • Page 29: Removing The Blade Server Bezel Assembly

    (RAID) level-1. See “Configuring a SCSI RAID Array” on page 42 for information about SCSI RAID configuration. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 30 2. Shut down the operating system, turn off the blade server, and remove the blade server from the Intel® Blade Server Chassis SBCE. See “Removing the Blade Server from an Intel® Blade Server Chassis SBCE” on page 17 for instructions. 3. Carefully lay the blade server on a flat, non-conductive surface.
  • Page 31: Removing A Sas Hard Disk Drive

    2. Shutdown the operating system, turn off the blade server, and remove the blade server from the Intel® Blade Server Chassis SBCE. See “Removing the Blade Server from an Intel® Blade Server Chassis SBCE” on page 17 for instructions. 3. Carefully lay the blade server on a flat, non-conductive surface.
  • Page 32 7. Touch the static-protective package that contains the DIMM option to any unpainted metal surface on the Intel® Blade Server Chassis SBCE or any unpainted metal surface on any other grounded rack component in the rack you are installing the DIMM option in for at least 2 seconds;...
  • Page 33: Installing Microprocessors

    When only a single microprocessor is to be installed, it must be installed in the microprocessor 1 socket (U66). ® • For a list of processors that are supported by your blade server, see the Intel Server Compute Blade SBXD62 Supported Processor List located on http:// support.intel.com).
  • Page 34 2. Shut down the operating system, turn off the blade server, and remove the blade server from the Intel® Blade Server Chassis SBCE. See “Removing the Blade Server from an Intel® Blade Server Chassis SBCE” on page 17 for instructions. 3. Carefully lay the blade server on a flat, static-protective surface.
  • Page 35 — Do not use excessive force when pressing the microprocessor into the socket. — Make sure that the microprocessor is oriented and aligned correctly in the socket before you try to close the lever. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 36 11.15 inch-pounds). Refer to the following illustration for recommended order to tighten screws. REPEAT SEQUENCE UNTIL TIGHT. 720˚ 720˚ AF000637 4. If you have other options to install or remove, do so now; otherwise, go to “Completing the Installation” on page Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 37: Installing An I/O-Expansion Card

    I/O-module bays 3 and 4 on the Intel® Blade Server Chassis SBCE. For example, if you add an Ethernet expansion card to a blade server installed in a Intel® Blade Server Chassis SBCE, the I/O-modules in I/O-module bays 3 and 4 must both be compatible with the expansion card.
  • Page 38: Replacing The Battery

    If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery contains lithium and can explode if not properly used, handled, or disposed of. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 39 “Installation Guidelines” on page 2. Follow any special handling and installation instructions that come with the battery. 3. Turn off the blade server and remove it from the Intel® Blade Server Chassis SBCE (see “Installing the Blade Server in an Intel® Blade Server Chassis SBCE” on page 32 for instructions).
  • Page 40: Completing The Installation

    Important: Hazardous energy is present when the blade server is connected to the power source. Always replace the blade cover before installing the blade server. 4. Reinsert the blade server into the bay in the Intel® Blade Server Chassis SBCE. 5. Turn on the blade server.
  • Page 41: Installing The Blade Server Bezel Assembly

    3. Carefully slide the bezel assembly onto the blade server until it clicks into place. Closing the Blade Server Cover Important: The blade server cannot be inserted into the Intel® Blade Server Chassis SBCE until the cover is installed and closed or an expansion unit is installed. Do not attempt to override this protection.
  • Page 42: Installing The Blade Server In An Intel® Blade Server Chassis Sbce

    If the blade server has an expansion unit installed on it, the blade server and expansion option require two adjacent bays. b. When any blade server or option is in blade bay 7 through 14 in a Intel® Blade Server Chassis SBCE, power modules must be present in all four power-module bays.
  • Page 43: Updating The Blade Server Configuration

    If this is the initial installation for the blade server in the Intel® Blade Server Chassis SBCE, you must configure the blade server through the Configuration/Setup Utility program and install the blade server operating system.
  • Page 44: Input/Output Connectors And Devices

    Input/Output Connectors and Devices The input/output connectors that are available to the blade server are supplied by the Intel® Blade Server Chassis SBCE. See the documentation that comes with the Intel® Blade Server Chassis SBCE for information about the input/output connectors.
  • Page 45: Configuring The Blade Server

    “Understanding the Control Panel and LEDs” on page 8 for information). — If you are managing the blade server from a remote location, see the Intel® Server Management Module SBCECMM User’s Guide, Intel® Management Module Command-Line Interface Reference Guide, or Serial over LAN (SOL) Setup Guide for information and instructions.
  • Page 46: Configuration/Setup Utility Menu Choices

    Select this choice to view information about the integrated video controller. — System MAC Addresses Select this choice to set and view the MAC addresses for the Ethernet controllers on the blade server. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 47 Hot Spare Memory pair of DIMMs to replace the failed memory pair of DIMMs. Before you can enable the memory mirroring or sparing, at least two pairs of DIMMs must be installed in the blade server that adhere to the Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 48 Select this choice to exit from the Configuration/Setup Utility program. If you have not saved the changes you have made in the settings, you are asked whether you want to save the changes or exit without saving them. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 49: Using Passwords

    2. Note: Shut down the operating system, turn off the blade server, and remove the blade server from the Intel® Blade Server Chassis SBCE to access the switches. Using the PXE Boot Agent Utility Program Use the Preboot Execution Environment (PXE) boot agent utility program to select the boot protocol and other boot options and to select a power-management option.
  • Page 50: Firmware Updates

    Firmware updates Intel will periodically make firmware updates available for the blade server. Use the following table to determine the methods that you can use to install these firmware updates. Important: To avoid problems and to maintain proper system performance, always make sure that the BIOS, service processor (BMC), and diagnostic firmware levels are consistent for all blade servers within the Intel®...
  • Page 51: Configuring The Gigabit Ethernet Controllers

    Important: To support failover on the blade server Ethernet controllers, the Ethernet switch modules in the Intel® Blade Server Chassis SBCE must have identical configurations. Blade Server Ethernet Controller Enumeration The enumeration of the Ethernet controllers in a blade server is operating-system dependent.
  • Page 52: Configuring A Scsi Raid Array

    I/O-module bays 3 and 4, if these bays are supported by your Intel® Blade Server Chassis SBCE. You can verify which controller on the card is routed to which I/O-module bay by performing the same test and using a controller on the expansion card and a compatible switch module or pass-thru module in I/O-module bay 3 or 4.
  • Page 53: Solving Problems

    • Diagnostic programs and error messages Real Time Diagnostics tests the major components of the Intel® Blade Server Chassis SBCE, including the management modules, I/O-modules, removable media drives, and the blade servers, while the operating system is running.
  • Page 54: Post Beep Code Descriptions

    POST. See “Diagnostics” in the Intel Server Compute Blade SBXD62 Hardware ® Maintenance Manual and Troubleshooting Guide on the Intel Server Compute Blade SBXD62 Resource CD for more information about POST error messages. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 55: Table 5. Abbreviated List Of Post Error Messages

    Have the system board serviced. checking hardware test. 012980xx Data for processor x Download and install the latest level of BIOS code. 012981xx 01298200 Microprocessor speed mismatch Install microprocessors with identical speeds. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 56: Troubleshooting Charts

    Install an operating system. system. Troubleshooting Charts ® The following tables list problem symptoms and suggested solutions. See the Intel Server Compute Blade SBXD62 Hardware Maintenance Manual and Troubleshooting ® Guide on the Intel Server Compute Blade SBXD62 Resource CD for more detailed troubleshooting charts.
  • Page 57: Microprocessor Problems

    If the problem remains, call for service. Only the cursor appears. Make sure that the keyboard, video, and mouse on the Intel® Blade Server Chassis SBCE have not been switched to another blade server. If the problem remains, call for service.
  • Page 58: Mouse Problems

    Make sure that the mouse is recognized as a USB device, not PS/2, by the blade server. Although the mouse might be a PS/2-style device, communication with the mouse is through an internal USB bus in the Intel® Blade Server Chassis SBCE. Some operating systems enable you to select the type of mouse during installation of the operating system.
  • Page 59: Network Connection Problems

    • The I/O-modules for the network interface that you are using are installed in communicate with the the correct bays and are configured and operating correctly. See the Intel® network. Blade Server Chassis SBCE Hardware Maintenance Manual and Troubleshooting Guide on the Resource CD that came with your Intel®...
  • Page 60: Power Problems

    The blade server does not Make sure that: turn on. a. The power LED on the front of the Intel® Blade Server Chassis SBCE is lit. b. The LEDs on all the power modules are lit. c. If the blade server or attached storage expansion unit is in blade bays 7 through 14 (in the Intel®...
  • Page 61: Light Path Diagnostics

    Light Path Diagnostics If the system-error LED on the system LED panel on the front or rear of the Intel® Blade Server Chassis SBCE is lit, one or more error LEDs on the components also might be lit. These LEDs help identify the cause of the problem.
  • Page 62 Power is available to relight the light path diagnostics LEDs for a small period of time after the blade server is removed from the Intel® Blade Server Chassis SBCE. During that period of time, you can relight the light path diagnostics LEDs for a maximum of 25 seconds (or less, depending on the number of LEDs that are lit and the length of time the blade server is removed from the chassis) by pressing the light path diagnostics button.
  • Page 63 Make sure that microprocessors 1 and 2 have the mismatch (MIS) same cache size and type and the same clock speed. Internal and external clock frequencies must be identical. If the problem remains, have the blade server serviced. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 64 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 65: A Warranty

    “as is” unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
  • Page 66: Warranty Limitations And Exclusions

    Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
  • Page 67: Telephone Support

    Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
  • Page 68 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 69: B Regulatory And Compliance Information

    CB Certificate & Report, IEC6095-1 (report to include all country national deviations) • GOST R 50377-92 - License (Russia) • CE - Low Voltage Directive 73/23/EEE (Europe) • CNS 14336 BSMI Certification (Taiwan) Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 70: Product Emc Compliance - Class A Compliance

    Product EMC Compliance - Class A Compliance This blade server has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed in a compatible Intel® host system. For information on compatible host system(s) contact your local Intel representative. •...
  • Page 71: Product Regulatory Compliance Markings

    EMC Marking (Class A) Canada VCCI Marking (Class A) Japan BSMI Certification Taiwan Number & Class A Warning GOST R Marking Russia RRL MIC Mark Korea See the regulatory information document for additional information. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 72: Electromagnetic Compatibility Notices

    All cables used to connect to peripherals must be shielded and grounded. Operation with cables, connected to peripherals, that are not shielded and grounded may result in interference to radio and TV reception. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 73: Industry Canada (Ices-003)

    Install and use the equipment according to the instruction manual. BSMI (Taiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 74: Korean Compliance (Rrl)

    5. Manufacturer/Nation: Intel Corporation/Refer to country of origin marked on product Restriction of Hazardous Substances (RoHS) Compliance Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration that materials banned in the RoHS Directive are either (1) below all applicable substance threshold limits or (2) an approved/pending RoHS exemption applies.
  • Page 75: C Safety Information

    Indicates hot components or surfaces. Indicates do not touch fan blades, may result in injury. Indicates to unplug all AC power cord(s) to disconnect AC power Please recycle battery Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 76: Intended Application Uses

    To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 77: System Access Warnings

    Turn off all peripheral devices connected to this product. • Turn off the system by pressing the power button to off. • Disconnect the AC power by unplugging all AC power cords from the system or wall outlet. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 78: Rack Mount Warnings

    Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 79: Other Hazards

    Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 80: Deutsch

    Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, bevor Sie Ihr Intel®...
  • Page 81: Zielbenutzer Der Anwendung

    Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 82 Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
  • Page 83: Warnhinweise Für Den Systemzugang

    Einbauen von Hot-Plug-Komponenten sorgfältig vor, um nicht mit heißen Komponenten in Berührung zu kommen. Vorsicht: Berühren Sie nicht die rotierenden Lüfterflügel, um Verletzungen zu vermeiden. Falls Ihr System mit eine Lüfterabdeckung besitzt, darf es nicht ohne diese Abdeckung betrieben werden. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 84: Elektrostatische Entladungen (Esd)

    Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 85: Andere Gefahren

    Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 86: Français

    Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant...
  • Page 87: Domaines D'utilisation Prévus

    • Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 88 Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
  • Page 89 Attention: Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre système est fourni avec une protection sur le ventilateur, ne mettez pas le système en route sans la protection en place. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 90: Décharges Électrostatiques (Esd)

    Utilisez si possible un tapi de mousse conducteru, mais pas l’emballage de la carte. Veillez à ce que la carte ne glisse sur aucune surface. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 91: Autres Risques

    Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au fabricant en cas de problème. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 92: Español

    Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , los gabinetes de servidor de ® Intel (montaje en rack y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y...
  • Page 93: Aplicaciones Y Usos Previstos

    Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 94 CA estén desenchufado antes de abrir le gabinete, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques eléctricos use precauciones al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
  • Page 95: Advertencias El Acceso Al Sistema

    Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 96: Descarga Electrostática (Esd)

    Utilice una almohadilla de espuma conductora si dispone de ella, pero nunca el envoltorio de la tarjeta. No deslice la tarjeta sobre ninguna superficie. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 97 • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 98 下面所列的安全符号可能在整个文档中使用并可能标注于产品和 / 或产品包装之上。 注意 表示如果无视此“? ? ? 项”? ? ? ? ? ? ? 轻微人身伤害或财产损失的危险。 警告 表示如果无视此“? ? ”? ? ? ? ? ? ? 严重人身伤害的危险。 表示如果无视所示信息,即存在潜在的危险。 表示如果不遵守安全指导,存在可导致严重伤害或死亡的电击危险。 表示灼热组件或表面。 表示请勿触摸风机叶片,否则可能致伤。 表示拔下所有交流电线,断开交流电源 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 99 • 与电气设备产生的强大电磁场隔离。 • 在易受闪电袭击的地区,我们建议将系统插入电涌抑制器并在闪电期间断开通信 线路与调制解调器之间的连接。 • 提供正确接地的墙壁插座。 • 提供足够的空间,以便拿取电源供应线,因为这是本产品的主要电源断开器。 设备操作规范 减少人身伤害或设备受损的危险: • 移举设备时遵守当地的职业健康与安全要求。 • 借助机械手段或其他合适的手段移举设备。 • 拆除一切易分离组件,以降低重量并方便操作。 电源与电气警告 注意事项 电源按钮(如待机电源标记所示)并不能完全关闭系统的交流电源,只要系统已接 通电源,就存在 5V 待机电源。要从系统切断电源,须从墙壁电源插座中拔下交流电线。您的系统可能 不止使用一根交流电线。请确保所有的交流电线都已拔下。打开机箱或增加或去除 任何热插拔组件之前,确保交流电线已拔下。 若非所需的确切类型,请勿尝试修改或使用交流电线。系统的每个电源供应设备都 需要一根单独的交流电线。 本产品的电源供应设备包含非用户维修部件。请勿打开电源供应设备。电源供应设 备包含非常危险的电压级、电流级和能量级。请与生产商联系维修事宜。 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线,再将其 从服务器上移除。 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 100 • 电源线为交流电源的主要断开设备。插座须靠近设备并可随时断开。 • 电源线须插入所提供的拥有合适接地的插座。 系统使用警告 注意事项 为避免人身伤害或财产损失,无论何时检查产品内部,以下安全指导都适用: • 关闭所有与本产品相连的外设。 • 按下电源按钮至关闭状态,关闭系统。 • 从系统或墙壁插座上拔下所有交流电线,断开交流电源。 • 断开与系统相连的所有线缆和通信线路。 • 卸除舱口盖时,保留所有螺钉及其他紧固件。完成产品内部检查之后,请 用螺钉或紧固件重新固定舱口盖。 • 请勿打开电源供应设备。电源供应设备内没有可维修部件。请与生产商联系 维修事宜. • 增加或替换任何非热插拔组件之前,请关闭服务器电源并断开所有电源线 。 • 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线 ,然后再从服务器上移除电源供应设备。 注意事项 如果服务器一直在运行,任何已安装的处理器和吸热设备都可能很热。除非要增加 或移除热插拔组件,否则请待系统冷却后再开盖。为避免在热插拔组件安装过程中 接触灼热组件,移除或安装热插拔组件时务须小心。 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 101 注意事项 为避免受伤,请勿触摸运转的风机叶片。如果系统的风机上配有防护装置,请勿卸 下风机防护装置运行系统。 机架固定件警告 设备的机架须固定在稳固的支座上,以防从中安装服务器或设备时倒塌。须按照机 架生产商提供的安装说明进行安装。 从下往上将设备安装在机架上,最重的设备安装在机架的最底层。 一次只从机架上安装一件设备。 您须负责安装整个机架装置的主要电源断开设备。此主要断开设备须随时可用,且 须标明为控制整个装置(而不仅限于服务器)的电源。 为避免潜在的电击危险,须对机架及其上所安装的每一件设备实行正确的安全接地 。 静电放电 (ESD) 注意事项 ESD 会损坏磁盘驱动器、主板及其他部件。我们建议您执行 ESD 工作站的所有步骤。如果没有 ESD 工作站,则采取一些静电放电保护措施,操作部件时,戴上与服务器上的机箱接地 或任何未喷漆金属表面连接的防静电腕带。 操作主板时始终保持小心。它们可能对 ESD 非常敏感。拿持主板时只接触边缘。从保护包装中或从服务器上取出主板后,请将 主板组件侧面朝上放置在无静电的接地表面上。请使用导电泡沫垫(若有),不要 使用主板包装。请勿将主板在任何表面上滑动。 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 102 其他危险 替换电池 注意事项 不正确替换电池可能导致爆炸危险。替换电池时,请只使用设备生产商推荐使用的 电池。 请按当地法规处置电池。 请勿对电池充电。 请勿拆卸、刺穿或以其他方式损坏电池。 冷却和气流 注意事项 按照说明小心布置线缆,尽量减少气流阻塞和冷却问题。 为保证适当的冷却和气流,运行系统时请确保机箱盖已安装。未安装机箱盖即运行 系统可能导致系统部件受损。安装机箱盖的步骤如下: 首先检查并确保系统内没有遗留的未固定工具或部件。 • 检查线缆、内插板和其他组件已正确安装。 • 按产品说明安装机箱盖。 • 激光外设或激光设备 注意事项 为避免幅射暴露和 / 或人身伤害: 请勿打开任何激光外设或激光设备的外壳 • 激光外设或激光设备为非用户维修设备 • 请与生产商联系维修事宜 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 103: D Getting Help

    Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). For an updated support contact list, see http://www.intel.com/support/9089.htm/...
  • Page 104: In Asia-Pacific Region

    Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 105 Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 106 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 107: E Installation/Assembly Safety Instructions

    1. Unlock and remove the padlock from the back of the system if a padlock has been installed. 2. Remove and save all screws from the covers. 3. Remove the cover(s). Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 108 • Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 109: Deutsch

    5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 110 Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 111 Telekommunikationsleitungen mit dem Modem bestehen; • "mit einer geerdeten Wechselstromsteckdose ausgerüstet sein; • "über ausreichend Platz verfügen, um Zugang zu den Netzkabeln zu gewährleisten, da der Stromanschluß des Produkts hauptsächlich über die Kabel unterbrochen wird Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 112: Français

    1. Si un cadenas a été installé sur à l'arrière du système, déverrouillez-le et retirez-le. 2. Retirez toutes les vis des panneaux et mettez-les dans un endroit sûr. 3. Retirez les panneaux. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 113 • "Muni d'une prise murale correctement mise à la terre. • "Suffisamment spacieux pour vous permettre d'accéder aux câbles d'alimentation (ceux-ci étant le seul moyen de mettre le système hors tension). Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 114: Español

    1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos de las tapas.Extraiga las tapas. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 115 "Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 116: Italiano

    1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 117 • "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. Intel® Server Compute Blade SBXD62 Installation and User’s Guide...
  • Page 118 Intel® Server Compute Blade SBXD62 Installation and User’s Guide...

Table of Contents