Intel SBXD62 - Server Compute Blade Installation And User Manual page 63

Server compute blade
Table of Contents

Advertisement

LED
DIMM x error
A memory error has occurred.
Processor x
The microprocessor has failed.
error
Temperature
The system temperature has
error (TEMP)
exceeded a threshold level.
System board
The system board has failed
error (S BRD)
NMI error
The system board has failed.
Processor
The processors do not match.
mismatch (MIS)
Intel® Server Compute Blade SBXD62 Installation and User's Guide
Problem
Replace the failing DIMM, which is indicated by the
lit DIMM failure LED.
NOTE: Multiple DIMM LEDs do not necessarily
If the problem remains, have the blade server
serviced.
Make sure that the microprocessor that is indicated
by the lit LED is installed correctly (see
Microprocessors" on page 23
instructions).
If the problem remains, replace the microprocessor.
If the problem remains, have the blade server
serviced.
Replace the blade server cover, reinsert the blade
server in the Intel® Blade Server Chassis SBCE,
and then restart the server.
If the problem remains, have the blade server
serviced.
If the problem remains, have the blade server
serviced.
Make sure that microprocessors 1 and 2 have the
same cache size and type and the same clock
speed. Internal and external clock frequencies must
be identical.
If the problem remains, have the blade server
serviced.
Action
indicate multiple DIMM failures. If more
than one DIMM LED is lit, reseat or replace
one DIMM at a time until the error is
corrected. Check the system error log in
the management module for information
about the error.
Determine whether a blower on the Intel®
Blade Server Chassis SBCE has failed. If it
has, replace the blower.
Make sure that the room temperature is not too
high (see
"Intel® Server Compute Blade
SBXD62 Specifications" on page 3
temperature information).
Replace the blade server cover, reinsert the
blade server in the Intel® Blade Server
Chassis SBCE, and then restart the server.
Check the system error log in the management
module for information about the error.