Removing The Cover - IBM 867413x - Eserver xSeries 330 8674 Hardware Maintenance Manual

Type 8674, intellistation r pro type 6851, and network equipment building system type 8674
Table of Contents

Advertisement

Removing the cover

The following information describes how to remove the cover.
Complete the following steps to remove the cover from the server/workstation:
1. Review the information in "Before you begin" on page 45.
2. Turn off the server/workstation and all attached devices and disconnect all
3. Remove the server/workstation from the rack (see "Rack installation" on
4. Remove the two screws from the rear of the server/workstation.
5. Pull out on the cover release lever at the back of the server/workstation, to
6. Slide the cover back, then up and off the server/workstation.
7. Remove the clear shield that covers the inside of the server/workstation.
48
Hardware Maintenance Manual: xSeries 330 Type 8674, IntelliStation R Pro Type 6851, and Network Equipment Building
System Type 8674
Cover release
lever
external cables and power cords.
page 46).
release the cover.
Attention:
For proper cooling and airflow, replace the cover before turning
on the server/workstation. Operating the server/workstation for extended
periods of time (over 30 minutes) with the cover removed might damage
server/workstation components.
Note: It is not necessary to remove the shield when you are installing memory
modules or installing an adapter in the PCI slots.
Screws