Power Checkout - IBM 867413x - Eserver xSeries 330 8674 Hardware Maintenance Manual

Type 8674, intellistation r pro type 6851, and network equipment building system type 8674
Table of Contents

Advertisement

Table 6. NDIS (Windows NT or Windows 2000) driver teaming messages for the Ethernet controller (continued)
Event ID
Type
04
Error
05
Error
06
Informational
07
Informational
08
Informational
09
Informational
10
Warning
11
Informational
12
Warning
13
Informational
14
Informational
15
Error
16
Informational
17
Informational
18
Informational
19
Informational
20
Informational
21
Warning

Power checkout

Power problems can be difficult to troubleshoot. For instance, a short circuit can
exist anywhere on any of the power distribution busses. Usually a short circuit will
cause the power subsystem to shut down because of an overcurrent condition.
A general procedure for troubleshooting power problems is as follows:
1. Power off the system and disconnect the AC cord(s). Disconnect all external
22
Hardware Maintenance Manual: xSeries 330 Type 8674, IntelliStation R Pro Type 6851, and Network Equipment Building
System Type 8674
Description
Explanation: Unable to bind to physical adapter. Action: Reconfigure the
adapter team by double-clicking the PROSet icon in the control panel.
Explanation: Unable to initialize an adapter team. Action: Reconfigure
the adapter team by double-clicking the PROSet icon in the control panel.
Explanation: Team nn. Primary adapter is initialized. Action: None.
Explanation: Team nn. Secondary adapter is initialized. Action: None.
Explanation: Team nn. Virtual adapter or Team is initialized. Action:
None.
Explanation: Team nn. Primary adapter is switching over. Action: None.
Explanation: Team nn. Adapter link down. Action: Make sure the
adapter is functioning properly.
Explanation: Team nn. Secondary adapter took over. Action: None.
Explanation: Team nn. Secondary adapter is deactivated from the Team.
Action: Make sure the secondary adapter is functioning properly and
that the adapter cable is securely connected to the LAN.
Explanation: Team nn. Secondary adapter has rejoined the Team. Action:
None.
Explanation: Team nn. Secondary adapter link is up. Action: None.
Explanation: Team nn. The last adapter has lost its link. Network
connection has been lost. Action: Shut down the server/workstation and
replace the adapters; then, restart the server/workstation to reestablish
the connection.
Explanation: Team nn. An adapter has re-established the link. Network
connection has been restored. Action: None.
Explanation: Team nn. Preferred primary adapter has been detected.
Action: None.
Explanation: Team nn. Preferred secondary adapter has been detected.
Action: None.
Explanation: Team nn. Preferred primary adapter took over. Action:
None.
Explanation: Team nn. Preferred secondary adapter took over. Action:
None.
Explanation: Team nn. Primary adapter does not sense any Probes.
Possible reason: partitioned Team. Action: Make sure the cables of the
adapter team are connected to the same LAN segment. Reconfigure the
team if necessary.
cables and remove server/workstation from the rack.