Using C2T; Cable Management - IBM 867413x - Eserver xSeries 330 8674 Hardware Maintenance Manual

Type 8674, intellistation r pro type 6851, and network equipment building system type 8674
Table of Contents

Advertisement

Using C2T

Placing several servers in a C2T chain enables you to share the same monitor,
keyboard, and mouse on all servers in the chain. To select a server, you can either
use the Console Select button on the front of the server that you want to select, or
you can use the keyboard. If you turn off a selected server, you must select another
server that is powered up. For the location of the Select button, see page 6.
To use the keyboard, do the following:
1. Press NumLock on the keyboard twice. The screen goes blank.
2. Type the number that corresponds to the server ID in the C2T chain. The screen
Server 1 (usually the server at the bottom of the rack) is the server to which you
connect the C2T breakout cable. Server 1 must not be turned off (powered down)
for the chain to work properly. If server 1 is turned off (powered down), it must be
removed from the chain and replaced by the next server in the chain.
Servers are numbered by their position in the chain (1 through n). If one server is
removed from the chain, all successive servers are renumbered. For example, if the
twelfth server is removed from a chain of 15 servers, servers 13 through 15 will
then be renumbered to 12 through 14.
When removing or replacing servers, or changing cables in the chain, it is possible
for more than one Select LED to be illuminated on the servers in the chain. To
clear all but the selected server LED, press the Select button on any one of the
servers in the chain.
If you are using a flat-panel monitor, you might need to adjust the image lock on
your monitor when multiple servers are connected using C2T interconnect cables.
To adjust this image, select one of the middle servers in the chain by pressing the
Select button on the front of the server; then, adjust the image lock accordingly. For
more information on how to adjust the image lock, see the documentation that
comes with your flat-panel monitor.
Note: For the chain to operate properly, no more than two adjacent servers can be

Cable management

Use the cable ties and hook-and-loop straps that are supplied with your server to
secure the cables.
Note: Do not secure cables too tightly. Overtightening can cause internal damage
112
Hardware Maintenance Manual: xSeries 330 Type 8674, IntelliStation R Pro Type 6851, and Network Equipment Building
System Type 8674
breakout cable directly to the C2T (Out) port of the server. Power-on the
server and retry the devices. If the devices work, you probably have a bad
C2T interconnect cable. Replace the cable and retry the devices in the C2T
chain configuration.
returns for the server that you selected, and the Console Select LED for that
server illuminates.
unplugged from the electrical outlet at the same time.
to cables.