Bus Fault Messages; Undetermined Problems - IBM 867413x - Eserver xSeries 330 8674 Hardware Maintenance Manual

Type 8674, intellistation r pro type 6851, and network equipment building system type 8674
Table of Contents

Advertisement

12C Buses x,y,...,z bad or devices on this bus are functioning incorrectly.
where the numbers listed x,y,...,z represent any of the buses that are experiencing a
fault. The table below provides the appropriate actions to take for each bus
number listed.
Message
Failure reading I2C device. Check devices
on bus 0.
Failure reading I2C device. Check devices
on bus 1.
Failure reading I2C device. Check devices
on bus 2.
Failure reading I2C device. Check devices
on bus 3.
Failure reading I2C device. Check devices
on bus 4.

Undetermined problems

You are here because the diagnostic tests did not identify the failure, the Devices
List is incorrect, or the system is inoperative. If this has occurred proceed as
follows:
Note: A corrupt CMOS can cause undetermined problems.
1. Ensure that the system is connected to an AC power source.
2. Press the power switch.
3. Are the power indicator LEDs (front and rear) ON or blinking?
134
Hardware Maintenance Manual: xSeries 330 Type 8674, IntelliStation R Pro Type 6851, and Network Equipment Building
System Type 8674
Action
1. Replace system board
1. Front Panel
2. Replace system board
1. Replace DASD backplane
2. Replace system board
1. Replace system board
1. Replace DIMM
2. Replace system board
Note: If AC power has been removed from system, allow 30 seconds after
restoring AC power before pressing power control button. See "Turning
on the server" on page 8.
Note: If system was powered-on when AC power was removed, system should
restart automatically when AC power is restored.
a. No. Check AC power into system. If AC power into system is good, suspect
the following FRUs in the order listed:
1) Power supply
2) System board
b. Yes, power indicators (front and rear) are blinking.
Turn switch 1 on switch block 1 to ON. If system powers-on, turn switch 1
on switch block 1 to OFF and replace front panel assembly. If system does
not power-on, reconfigure system to minimum operating requirements and
retry. If problem remains, suspect the following FRUs in the order listed:
1) Power supply
2) System board
c. Yes, power indicator LEDs (front and rear) are ON.
1) Power-off system.
2) Ensure system is cabled correctly.
3) Reconfigure system to minimum operating requirements.
Note: Minimum operating requirements are:

Advertisement

Table of Contents
loading

This manual is also suitable for:

867431x - eserver xseries 330Eserver xseries 330

Table of Contents