Fan Error Messages; System Shutdown; Voltage Related System Shutdown - IBM 867413x - Eserver xSeries 330 8674 Hardware Maintenance Manual

Type 8674, intellistation r pro type 6851, and network equipment building system type 8674
Table of Contents

Advertisement

Message
DASD 1 Over Temperature (level-critical;
sensor for DASD1 reported temperature
over recommended range)
Power Supply "X" Temperature Fault
(level-critical; power supply "x" had over
temperature condition)
System board is over recommended
temperature (level-warning; system board
is over recommended temperature)
System board is under recommended
temperature (level-warning; system board
is under recommended temperature)
System over temperature for CPU "X"
(level-warning; CPU "X" reporting over
temperature condition)
System under recommended CPU "X"
temperature (level-warning; system
reporting under temperature condition for
CPU "X")

Fan error messages

Message
Fan "X" failure (level-critical; fan "X" had a
failure)
Fan "X" fault (level-critical; fan "X" beyond
recommended RPM range)
Fan "X" Outside Recommended Speed
Action

System shutdown

Refer to the following tables when experiencing system shutdown related to
voltage or temperature problems.

Voltage related system shutdown

Message
System shutoff due to "X" current over
max value (level-critical; system drawing
too much current on voltage "X" bus)
System shutoff due to "X" current under
min. value (level-critical; current on
voltage bus "X" under minimum value)
System shutoff due to "X" V over voltage
(level-critical; system shutoff due to "X"
supply over voltage)
132
Hardware Maintenance Manual: xSeries 330 Type 8674, IntelliStation R Pro Type 6851, and Network Equipment Building
System Type 8674
Action
1. Ensure system is being properly cooled; see "Temperature
checkout" on page 25.
1. Ensure system is being properly cooled; see "Temperature
checkout" on page 25.
2. Replace Power Supply "X"
1. Ensure system is being properly cooled; see "Temperature
checkout" on page 25.
2. Replace system board
1. Ambient temperature must be within normal operating
specifications; see "Features and specifications" on page 4.
1. Ensure system is being properly cooled; see "Temperature
checkout" on page 25.
1. Ambient temperature must be within normal operating
specifications; see "Features and specifications" on page 4.
Action
1. Check connections to fan "X"
2. Replace fan "X"
1. Check connections to fan "X"
2. Replace fan "X"
1. Replace Fan "X"
Action
1. See "Power checkout" on page 22.
1. See "Power checkout" on page 22.
1. Check power supply connectors
2. Replace power supply