1. If you completed the procedure for configuring the serial port and the
Configuration Settings window is open, go to step 6; otherwise, continue with
step 2.
2. Turn on the server.
3. Insert the IBM Remote Supervisor Adapter Support CD into the CD-ROM drive
and close the CD-ROM drive before the server completes POST.
Note: If you do not insert the CD and close the CD-ROM drive before POST
completes, you must restart the server with the CD in the CD-ROM
drive.
4. The CD starts automatically and the IBM Remote Supervisor Utility window
opens.
5. Use the Up Arrow and Down Arrow keys ( and ) to select Configuration
Settings; then, press Enter.
The Configuration Settings window opens.
6. Use the arrow keys to select PPP Settings; then, press Enter.
The PPP Settings window opens.
Note: The values in the following windows are only examples; your settings
will be different
7. Use the arrow keys to navigate to each field. Verify the values in the following
fields:
Network Interface
The default is Disabled. Change this field to Enabled.
IP Address
The default value is 192.96.1.1. Make sure that the client is configured
to allow the server to assign this IP Address.
Subnet Mask
The default value is 255.255.255.255.
Line Type
The default is PPP.
Remote IP Address
The default value is 192.96.1.2.
75