Atm1483Vcclass - Juniper JUNOSE SOFTWARE FOR E SERIES 11.3.X - SYSTEM EVENT LOGGING REFERENCE GUIDE 2010-10-04 Reference Manual

Software for e series broadband services routers system event logging reference guide
Hide thumbs Also See for JUNOSE SOFTWARE FOR E SERIES 11.3.X - SYSTEM EVENT LOGGING REFERENCE GUIDE 2010-10-04:
Table of Contents

Advertisement

JunosE 11.3.x System Event Logging Reference Guide
Alert
Critical
Error
Warning Log
Notice Log
Info
Debug
Filter

atm1483VcClass

Description
Emergency
Alert
Critical
Error
Warning Log
Notice Log
30
None
None
Error applying static map entry for a newly created circuit of an NBMA interface; unable
to configure interfaces on ATM interface; unable to determine interface location for ATM
AAL5 interface; unable to determine maximum interface configuration count for interface;
unable to configure interface on ATM interface
Error getting location of underlying AAL5 or ATM interface; error binding to AAL5 interface;
error opening a circuit for an NBMA interface; attempting to associate a static map to an
underlying ATM interface that does not exist; error restoring circuits from NVS; error
removing static map entry; NVS entry not found for static map entry; error storing static
map entry in NVS; error expanding interface pool, interface binding pool, or subscriber
pool
Interface pool, interface binding pool, or subscriber pool expanded by an incremental
number of entries; unable to allocate a message to send a subinterface up or down
notification
Dropping subinterface up or down notification due to removal of subinterface; configure
interfaces on ATM interface; elapsed time for downloading interfaces; elapsed time for
ATM AAL5 present notification; maximum interface count per call
None
None
Application of attributes configured in a virtual circuit (VC) class to PVCs
None
None
None
In routers with high availability enabled, failure to mirror the VC modification or failure
to associate the VC modification with the standby SRP module
Failure to find the PVCs associated with this VC class; failure to apply the VC class
attributes to the appropriate PVCs; the log message displays a brief description of the
failure
None
Copyright © 2010, Juniper Networks, Inc.