Juniper JUNOSE SOFTWARE FOR E SERIES 11.3.X - SYSTEM EVENT LOGGING REFERENCE GUIDE 2010-10-04 Reference Manual page 32

Software for e series broadband services routers system event logging reference guide
Hide thumbs Also See for JUNOSE SOFTWARE FOR E SERIES 11.3.X - SYSTEM EVENT LOGGING REFERENCE GUIDE 2010-10-04:
Table of Contents

Advertisement

JunosE 11.3.x System Event Logging Reference Guide
log engineering
log fields
log here
8
Example
host1(config)#log destination syslog 10.1.2.3 source atm 0/1
Use the no version to restore the actual source interface type and location.
See log destination syslog source.
Use to enable engineering logs.
Provides troubleshooting information to assist you when contacting Juniper Networks
Technical Assistance Center (JTAC).
Example
host1(config)#log engineering
Use the no form of this command to disable engineering logs.
See log engineering.
Use to select fields to be added to all logs. These fields include a timestamp for the
message, an instance identifier, and the name of the internal software application that
created the message.
Example
host1(config)#log fields timestamp instance no-calling-task
Use the no version to restore the default log field settings.
See log fields.
Use to enable logs destined for a console to be displayed at the current console.
By default, the local console automatically receives all log messages if console is a
destination. The exception is the cliCommand log, whose log events do not appear on
the console.
By default, Telnet consoles do not receive log messages.
Example
host1#log here
Use the no version to disable logs destined for a console from being displayed on this
console.
See log here.