To configure E1 R2 signalling, use the following commands beginning in global configuration mode:
Command
Step 1
AS5350> enable
Password: password
AS5350#
Step 2
AS5350# configure terminal
Enter configuration commands, one per line.
End with CNTL/Z.
AS5350(config)#
Step 3
AS5350(config)# controller e1 0/0
AS5350(config-controller)#
Step 4
AS5350(config-controller)# ds0-group 1
timeslots 1-30 type r2-analog r2-compelled
ani
Step 5
AS5350(config-controller-cas)# cas-custom 1
Step 6
AS5350(config-ctrl-cas)# country country
use-default
OL-3418-02 B0
Cisco AS5350 and Cisco AS5400 Universal Gateway Software Configuration Guide
Configuring E1 R2 Signaling
Purpose
Enters enable mode (also called privileged EXEC
mode) and enter the password. You are in enable
mode when the prompt changes to
.
AS5400#
Enters global configuration mode. You are in
global configuration mode when the prompt
changes to
AS5350(config)#
Enters controller configuration mode to configure
your E1 controller port.
Specifies E1 controller dfc-slot, port number, and
channel. On the CE1 trunk card, port-number
values range from 0 to 1.
Configures the timeslots that belong to each E1
circuit for R2 signaling. Sets R2 signaling to R2
ITU Q411, the tone signal to R2 compelled
register signaling, and the ANI addr info
provisioned option.
R2 line signaling options include r2-analog,
r2-digital, and r2-pulse.
Tone signaling options include dtmf (default),
r2-compelled, r2-non-compelled, and
r2-semi-compelled.
You can also set ani (ANI address information
provisioned) for any of the above options
Enters the channel number to customize.
Uses defaults for the specified country.
To view the parameters for the country (if
Note
the country defaults are the same as ITU
defaults), enter write term.
The default setting for all countries is ITU.
See
"Country Codes for R2 Signaling" section on
page 4-9
for a list of supported countries.