Configure; Verify - Cisco AS5350 - Universal Access Server Configuration Manual

Universal gateway software configuration guide
Hide thumbs Also See for AS5350 - Universal Access Server:
Table of Contents

Advertisement

Configuring a Channelized T3 Trunk Card

Configure

Command
Step 1
AS5400> enable
Password: password
AS5400#
Step 2
AS5400# configure terminal
Enter configuration commands, one per line.
End with CNTL/Z.
AS5400(config)#
Step 3
AS5400(config)# controller t3 1/0
AS5400(config-controller)#
Step 4
AS5400(config-controller)# framing c-bit
Step 5
AS5400(config-controller)# clock source
line
Step 6
AS5400(config-controller)# cablelength 450
Step 7
AS5400(config-controller)# t1 1-28
controller
or
AS5400(config-controller)# t1 1-10,15-20,23
controller
Step 8
AS5400(config-controller)# Ctrl-Z
AS5400#

Verify

To verify that your controller is up and running and no alarms have been reported:
Cisco AS5350 and Cisco AS5400 Universal Gateway Software Configuration Guide
3-12
Enter the show controller command and specify the controller type, slot, and port numbers:
AS5400# show controller t3 1/0
T3 1/0 is down.
Applique type is Channelized T3
Transmitter is sending remote alarm.
Receiver has loss of signal.
FEAC code received: No code is being received
Framing is M23, Line Code is B3ZS, Clock Source is Line
Data in current interval (330 seconds elapsed):
0 Line Code Violations, 0 P-bit Coding Violation
0 C-bit Coding Violation, 0 P-bit Err Secs
0 P-bit Severely Err Secs, 0 Severely Err Framing Secs
0 Unavailable Secs, 0 Line Errored Secs
0 C-bit Errored Secs, 0 C-bit Severely Errored Secs
Total Data (last 24 hours)
Chapter 3
Basic Configuration Using the Command-Line Interface
Purpose
Enters enable mode. Enters the password. You are
in enable mode when the prompt changes to
or
.
AS5350#
AS5400#
Enters global configuration mode. You are in
global configuration mode when the prompt
changes to
AS5350(config)#
AS5400(config)#.
Enters controller configuration mode to configure
your T3 controller for slot 1 port 0. Slot values
range from 1 to 7. Port number is always 0.
Enters your telco's framing type: c-bit or m23.
Enters your clock source:
Enters your cablelength: values range from 0 to
450 feet.
Configures your T1 controllers. Range is 1 to 28.
In this instance, all 28 T1s are configured at once.
or
Omits specified T1 controllers while provisioning
others. In this instance, T1 controllers 11-14, 21,
22, and 24-28 are unprovisioned.
This CLI command is backward
Note
compatible only.
Returns to enable mode.
or
or
.
internal
line
OL-3418-02 B0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

As5400