Rmon Alarm Configuration - HP GbE2c - Blc Layer 2/3 Fiber SFP Option Cli Reference Manual

Hp gbe2c ethernet blade switch for c-class bladesystem iscli reference guide
Hide thumbs Also See for GbE2c - Blc Layer 2/3 Fiber SFP Option:
Table of Contents

Advertisement

Table 166
RMON Event commands
Command
rmon event <1-65535> owner <1-
127 characters>
no rmon event <1-65535>
show rmon event

RMON alarm configuration

The Alarm RMON group can track rising or falling values for a MIB object. The MIB object must be a counter, gauge,
integer, or time interval. Each alarm index must correspond to an event index that triggers once the alarm threshold is
crossed.
The following table describes the RMON Alarm commands.
Table 167
RMON Alarm commands
Command
rmon alarm <1-65535> alarm
oid <1-127 characters>
rmon alarm <1-65535> interval
<1-65535>
rmon alarm <1-65535>
sample {abs|delta}
rmon alarm <1-65535> alarm-
type {rising|falling|either}
rmon alarm <1-65535> rising-
limit <-2147483647 to
2147483647>
rmon alarm <1-65535> falling-
limit <-2147483647 to
2147483647>
rmon alarm <1-65535> rising-
crossing-index < 0-65535>
rmon alarm <1-65535> falling-
crossing-index < 0-65535>
rmon alarm <1-65535> owner
<1-127 characters>
Description
Enter a text string that identifies the person or entity that uses this event
index.
The owner can have a maximum of 127 characters.
Command mode: Global configuration
Deletes this event index.
Command mode: Global configuration
Displays the current RMON Event parameters.
Command mode: All
Description
Configures an alarm MIB Object Identifier.
The alarm OID can have a maximum of 127 characters.
Command mode: Global configuration
Configures the time interval over which data is sampled and compared with
the rising and falling thresholds.
The range is from 1 to 65535 seconds. The default is 1800 seconds.
Command mode: Global configuration
Configures the method of sampling the selected variable and calculating the
value to be compared against the thresholds, as follows:
abs: absolute value, the value of the selected variable is compared directly
with the thresholds at the end of the sampling interval.
delta: delta value, the value of the selected variable at the last sample is
subtracted from the current value, and the difference compared with the
thresholds.
Command mode: Global configuration
Configures the alarm type as rising, falling, or either (rising or falling).
Command mode: Global configuration
Configures the rising threshold for the sampled statistic. When the current
sampled value is greater than or equal to this threshold, and the value at the
last sampling interval was less than this threshold, a single event is generated.
Command mode: Global configuration
Configures the falling threshold for the sampled statistic. When the current
sampled value is less than or equal to this threshold, and the value at the last
sampling interval was greater than this threshold, a single event is generated.
Command mode: Global configuration
Configures the rising alarm event index that is triggered when a rising
threshold is crossed.
The range is from 0 to 65535. The default value is 0.
Command mode: Global configuration
Configures the falling alarm event index that is triggered when a falling
threshold is crossed.
The range is from 0 to 65535. The default value is 0.
Command mode: Global configuration
Enter a text string that identifies the person or entity that uses this alarm index.
The owner can have a maximum of 127 characters.
Command mode: Global configuration
Configuration Commands 137