Download Print this page

ITech IT6341C User Manual page 27

Dual channel programmable dc power supply

Advertisement

The Protect menu is shown in the table below.
Protection function menu in power mode
Protect
FOLDB
OVP
OCP
UCP
Foldback protection function. Default is OFF.
Selecting CC indicates that the instrument triggers protection and
outputs OFF when the instrument's operation mode is switched
from non-CC mode to CC mode.
After selecting CC, you also need to set the DELAY protection delay
time. Setting range: 0.0000~10, default 10s.
Selecting CV indicates that the instrument triggers protection and
outputs OFF when the instrument's operation mode is switched
from non-CV mode to CV mode.
After selecting CV, you also need to set the DELAY protection delay
time. Setting range: 0.0000~10, default 10s.
Select OFF in to indicate that the foldback function is turned off.
Over-voltage protection function
Disabling the OVP function (Def)
Off
Turn on the OVP function
On
OVP
DELAY
Overcurrent protection function
Disabling the OCP function (Def)
Off
Turn on the OCP function
On
OCP
DELAY
Undercurrent protection function
Disabling the UCP function (Def)
Off
Turn on the UCP function
On
Copyright © Itech Electronic Co., Ltd.
OVP Protection Point
Protection delay time.
Setting range: 0.00~10S, step 0.01S,
default 10S
OCP Protection Point
Protection delay time.
Setting range:
0.00~10S, step 0.01S, default 10S