MAINTENANCE FUNDAMENTALS, CONTINUED - LED STYLE LIGHT FIXTURES
LED Style Light Fixtures
Removal of Faulty LED Lights:
LED lights rarely require change-out.
Contact Structural Concepts' Technical Service
Department for replacement LED lights.
Turn off LED light switch.
To remove faulty LED light, follow these steps:
A. Disconnect plug from LED light.
B. Using both hands, grasp LED light assembly
(with its magnetic mounting clips). Pull
downward and off its shelf (or header).
C. Remove magnetic mounting clips from LED
light by pressing against flange part of clip
with thumb.
>> Note: Mounting clips MAY be riveted to shelf or
header. In such instances, simply remove LED light
from mounting clips by pressing against flange part
of clips with thumb.
LED
Shaped
Light
B
Magnetic Mounting
Clip View #1
A
Plug
Barrel
Insert
LED
Lights
C
Magnetic Mounting
Clip View #2
Replacement of LED lights:
Attach magnetic mounting clips onto LED light.
Adjust magnetic mounting clips so they are equally
spaced on LED light.
Reattach LED light assembly to its shelf/header.
Position properly in shelf/header.
>> Note: If mounting clips are riveted to shelf (or
header), attach by placing LED in base of clip and
then snapping into clip at FLANGE SIDE.
Press plug's barrel-shaped insert all the way into
LED light.
Important: If plug is not inserted ALL THE WAY IN
the LED light's orifice, the light may not energize.
See
"BAD"
vs.
"GOOD"
below-right.
Turn LED light switch back on.
Light
Fixtures (Typ.)
--- Random Model Shown Above For Illustrative Purpose Only ---
Gap
22
insertion illustrations
No Gap