Chapter 2 Front Panel
• Auto-crossover or auto-MDI/MDI-X. The port automatically works with a
straight-through or crossover Ethernet cable.

2.2.2 CONSOLE Port

For local management through the command line interface (CLI), use a computer
with terminal emulation software configured to the following parameters:
• VT100 terminal emulation
• 9600 bps
• No parity, 8 data bits, 1 stop bit
• No flow control
Connect the male 9-pin end of the console cable to the CONSOLE port of the MM-
7201. Connect the female end to a serial port (COM1, COM2 or other COM port) of
your computer.

2.2.3 ALARM Port

The ALARM port has input pins and output pins.
A closed circuit on the ALARM input pins indicates an alarm. Pins 3 and 7 are
alarm input one. Pins 4 and 8 are alarm input two. Pins 5 and 9 are alarm input 3.
The MM-7201 signals an alarm when it detects an alarm on the ALARM input pins
or in the MS-7206 system (for example, the voltage or temperature is outside the
normal range). To signal an alarm, the MM-7201 opens the circuit for pins 1 and 6
(the common pin) and closes the circuit for pins 2 and 6.
Figure 4 ALARM Pins Layout
Pin 1
Pin 9
32
Pin 5
Pin 6
MS-7206 User's Guide