A702 MFR too long in dosing state (<P1> minutes)
Wrong time setting
The MFR dosing/driving time
takes longer than the set
timeout time.
Bumper is activated many times
If the bumper of the MFR is
activated many times by e.g.
cows/bulls it takes too long
before the MFR is back in the
feed kitchen.
The MFR did not return from the
route
The MFR is in alarm outside the
range of the PDB bluetooth
connection. It has for instance
driven into an obstacle and is
stuck in the route.
7-12
Solution:
Drive and feed on the largest
route with the largest feed
location, time it and add half of
the time to it. Set this time value
to the setting Max MFR dose
time.
Solution:
Add some time to the set Max
MFR dose time.
Solution:
Solve and reset the alarm and
resume the route.
in n o vato rs in ag ric u ltu re
Preventive measure:
Set the dosing time using the
rule of thumb and adjust it when
necessary.
Preventive measure:
Set the dosing time using the
rule of thumb and adjust it when
necessary. Consider to install the
optional electric bumper
protection on the MFR, for
information ask the Lely Center.
If possible make the feeding
distance between the fence and
the MFR a little bit wider.
Preventive measure:
Extending the range of the PDB
by adding repeater nodes so the
initial alarm is immediately
forwarded to the farmer and
rapid action can be taken.