2.
If necessary test the charging on the lely control app:
1.
Connect the smartphone (see Connect the Smartphone to Device Software on page 5-15) to
the Mixing and Feeding Robot.
2.
Select the page Test > Batt chargers.
The battery voltage (0.1 volt) and the current (mA) of each battery is displayed.
3.
Push
to go to the next page.
The BattStat and LoadPhase are displayed for each battery. See explanation in the table
below.
4.
Push
to go to the previous page.
Explanation BattStat
0= Battery wait
1= Battery charge
2= Battery half full
3= Battery full
–1= No charge current
–2= Battery timeout
–3= Battery error
–4= No start current
The Mixing and Feeding Robot must charge for at least one hour.
7.4
Release a Jammed Mixer
Do this procedure when the mixer is jammed for example because there is too much feed with long fibers
in one place.
Turn the mixer in the opposite direction
1.
Connect the smartphone (see Connect the Smartphone to Device Software on page 5-15) to the Mixing
and Feeding Robot.
2.
Select the page Test > Test motors > Mixer.
3.
Push
.
4.
Push
a few seconds until the mixer is turning.
5.
Push
.
6.
Push
a few seconds until the mixer is turning smoothly,
if the mixer does not turn, the feed must be removed.
7-18
Explanation LoadPhase
0= Pre settings
2= Current check
3= Main charge state
4= Second charge state
5= Settings
7= Post charge state
9= Battery full
10= Charging finished
29= Start route
30= Charging error
in n o vato rs in ag ric u ltu re