Operation
General Reader Configuration
Commands
The red and green LEDs and buzzer can be configured to be
under host control, or the printer 's control. The printer can
control the LEDs only if EITHER the MAG card read is en-
abled, OR the Smart Card is enabled, but not both. If the
LEDs are configured to be under host control, the MG and
MR commands will override the printer 's current use of the
LED:
Command: {CCR:data}
figuration – requires data
CCR data: HOST – LEDs and BEEPER are under host con-
trol
AUTO – LEDs and BEEPER are under reader 's control:
If MAG card enabled and ICC Smart Card disabled:
"
"
"
If ICC Smart Card enabled and MAG card disabled
"
"
"
Magnetic Card Operational
Commands
The magnetic card reader is always operating in the back-
ground if it is enabled. Magnetic card data is read when
the card is inserted, removed, or both (default is read on
removal only). That data read is stored in the printer until
the data is zeroed or the printer falls asleep. Temporary
4-40
Intermec Portable Printers Technical Reference Manual
Flashing Green – card inserted
Solid Green (timed) + 2 short beeps – good read
Solid Red (timed) + 1 long beep – bad read
Flashing Green – card inserted
Solid Red – card inserted and ICC power ON
Solid Green (timed) – card inserted and ICC power
turned OFF
Reader LED and BEEPER con-
SECTION 4