Interdigit Short Timer (Complete Entry Timer)

You can think of this timer as the "complete entry" timer. This timer measures the interval
between dialed digits. It applies when the dialed digits match at least one digit sequence in the
dial plan. Unless the user enters another digit within the specified number of seconds, the entry
is evaluated. If it is valid, the call proceeds. If it is invalid, the call is rejected. The default value is
3 seconds.
Syntax for the Interdigit Short Timer
SYNTAX 1:
:s,
S
( dial plan )
Use this syntax to apply the new setting to the entire dial plan within the parentheses.
SYNTAX 2: sequence
Use this syntax to apply the new setting to a particular dialing sequence.
– s: The number of seconds; if no number is entered after
seconds applies.
Examples for the Interdigit Short Timer
Set the timer for the entire dial plan.
EXAMPLE:
S:6,
(9,8<:1408>[2-9]xxxxxx | 9,8,1[2-9]xxxxxxxxx | 9,8,011xx. | 9,8,xx.|[1-8]xx)
While entering a number with the phone off hook, a user can pause for up to 15
S:6,
seconds between digits before the Interdigit Short Timer expires. This setting is
especially helpful to users such as sales people, who are reading the numbers from
business cards and other printed materials while dialing.
Set an instant timer for a particular sequence within the dial plan.
EXAMPLE:
(9,8<:1408>[2-9]xxxxxx |
9,8,1[2-9]xxxxxxxxxS0
the user dials the final digit in the sequence.

Editing Dial Plans

You can edit dial plans and can modify the control timers.
Entering the Line Interface Dial Plan
This dial plan is used to strip steering digits from a dialed number before it is transmitted out to
the carrier.
1. Connect to the administration web server, and choose Admin access with Advanced
settings.
2. Click Voice tab > Line N, where N represents the line interface number.
3. Scroll down to the Dial Plan section.
Linksys ATA Administration Guide
Ss
9,8,1[2-9]xxxxxxxxxS0
With the timer set to 0, the call is transmitted automatically when
Configuring Dial Plans
, the default timer of 5
S
| 9,8,011xx. | 9,8,xx.|[1-8]xx)