International Control (Settings) section

Field
Description
FXO Port Impedance
Desired impedance of the FXO Port. Choose from {600, 900, 370+620,
270+750||150nF, 220+820||120nF, 370 + 620 || 310nf, 320 + 1050 ||
230nf, 370 + 820 || 110 nf, 275 + 780 || 115nf, 120 + 820 || 110nf, 350 +
1000 || 210nf, 0 + 900 || 130nf }
The default is 600.
The Disconnect Tone Script and Impedance values for various countries
follos:
US—480@-30,620@-30;4(.25/.25/1+2) —Impedance: 600
UK—400@-30,400@-30; 2(3/0/1+2) —Impedance: 370+620
France—440@-30,440@-30; 2(0.5/0.5/1+2) —Impedance: 270+750||150nF
Germany—425@-10; 10(0.48/0.48/1) —Impedance:220+820||120nF
Netherlands—425@-30,425@-30; 2(0.5/0.5/1+2) —Impedance: 600
Sweden—425@-10; 10(0.25/0.25/1) —Impedance:600
Norway—425@-10; 10(0.5/0.5/1) —Impedance: 600
Italy—425@-30,425@-30; 2(0.2/0.2/1+2)— Impedance: 220+820||120nF
Spain—425@-10; 10(0.2/0.2/1,0.2/0.2/1,0.2/0.6/1) —Impedance:
220+820||120nF
Portugal—425@-10; 10(0.5/0.5/1)— Impedance:220+820||120nF
Poland—425@-10; 10(0.5/0.5/1)— Impedance: n/a
Denmark—425@-10; 10(0.25/0.25/1)— Impedance: 600
Ring Frequency Min
Specify the lower limit of the ring frequency used to detect the ring signal.
The default is 10.
SPA To PSTN Gain
dB of digital gain (or attenuation if negative) to be applied to the signal sent
from the SPA to the PSTN side. The range is -15 to 12.
The default is 0.
Ring Frequency Max
Specify the higher limit of the ring frequency used to detect the ring signal.
The default is 100.
PSTN To SPA Gain
dB of digital gain (or attenuation if negative) to be applied to the signal sent
from the PSTN side to the SPA. The range is -15 to 12.
The default is 0.
Ring Validation Time
Specify the minimum signal duration required by the Gateway for
recognition as a ring signal. The default is 256 ms.
Tip/Ring Voltage Adjust Choices are {3.1, 3.2, 3.35, 3.5}.
The default is 3.5.
Operational Loop
Choices for mA are: {10, 12, 14, 16).
Current Min
The default is 10.
On-Hook Speed
Choose from {Less than 0.5ms, 3ms (ETSI), 26ms (Australia)}.
The default is Less than 0.5ms.
Current Limiting Enable Enable or disable current limiting.
The default is no.
Ring Frequency Min
Minimum ring frequency to detect. The range is 5-100.
The default is 10.
Linksys ATA Administration Guide
PSTN Line page (AG310 and SPA3102)
155