Miscellaneous Settings Section (Not Used With Pap2T) - Linksys RTP300 - Broadband Router With 2 Phone Ports Administration Manual

User guide
Hide thumbs Also See for RTP300 - Broadband Router With 2 Phone Ports:
Table of Contents

Advertisement

Field
Description
Secondary DNS
Sets the secondary DNS server to take over if problems are discovered with
the Primary DNS server. This is in addition to DHCP-supplied DNS servers if
DHCP is enabled; when DHCP is disabled, this is the secondary DNS server.
The default is 0.0.0.0.
DNS Server Order
Specifies the method for selecting the DNS server. The options are Manual
(enter the IP address of the DNS server manually; that is do not look at the
DHCP-supplied DNS table), Manual/DHCP, and DHCP/Manual.
DNS Query Mode
Do parallel or sequential DNS Query. With parallel DNS query mode, the
ATA device sends the same request to all the DNS servers at the same time
when doing a DNS lookup, the first incoming reply is accepted by the ATA
device.
The default is parallel.
Syslog Server
Specify the syslog server name and port. This feature specifies the server for
logging ATA device system information and critical events. If both Debug
Server and Syslog Server are specified, Syslog messages are also logged to
the Debug Server.
Debug Server
The debug server name and port. This feature specifies the server for logging
ATA device debug information. The level of detailed output depends on the
debug level parameter setting.
Debug Level
The higher the debug level, the more debug information is generated. Zero
(0) means no debug information is generated. To log SIP messages, Debug
Level must be set to at least 2.
The default is 0.
Primary NTP Server
IP address or name of primary NTP server.
Secondary NTP Server
IP address or name of secondary NTP server.
Voice tab > System page >

Miscellaneous Settings section (not used with PAP2T)

Field
Description
Syslog Server
Specifies the IP address of the syslog server.
Debug Server
Specifies the IP address of the debug server, which logs debug information.
The level of detailed output depends on the debug level parameter setting.
Debug Level
Determines the level of debug information that is generated. Select 0, 1, 2, or
3 from the drop-down menu. The higher the debug level, the more debug
information is generated.
The default is 0, which indicates that no debug information is generated.
Linksys ATA Administration Guide
System page
101

Advertisement