Ethernet CFM and Ethernet OAM Interaction

Enabling Ethernet OAM

Beginning in privileged EXEC mode, follow these steps to enable Ethernet OAM on an interface.
Command
Step 1
configure terminal
Step 2
interface interface-id
Step 3
ethernet oam [max-rate oampdus | min-rate
seconds | mode {active | passive} | timeout seconds]
Step 4
end
Step 5
copy running-config startup-config
Step 6
show ethernet cfm maintenance points remote

Ethernet OAM and CFM Configuration Example

These are example configurations of the interworking between Ethernet OAM and CFM in a sample
service provider network with a provider-edge switch connected to a customer edge switch at each
endpoint. You must configure CFM, E-LMI, and Ethernet OAM between the customer edge and the
provider edge switch.
Customer-edge switch 1 (CE1) configuration:
Switch# config t
Switch(config)# interface gigabitethernet0/1
Switch(config-if)# port-type nni
Switch(config-if)# switchport trunk allowed vlan 10
Switch(config-if)# switchport mode trunk
Switch(config-if)# ethernet oam remote-loopback supported
Switch(config-if)# ethernet oam
Switch(config-if)# exit
Provider-edge switch 1 (PE1) configuration:
Switch# config t
Switch(config)# interface gigabitethernet0/5
Switch(config-if)# switchport trunk encapsulation dot1q
Switch(config-if)# switchport mode trunk
Switch(config-if)# ethernet cfm mip level 7
Switch(config-if)# ethernet cfm mep level 4 mpid 100 vlan 10
Cisco ME 3400 Ethernet Access Switch Software Configuration Guide
41-34
Chapter 41
Configuring Ethernet OAM, CFM, and E-LMI
Purpose
Enter global configuration mode.
Define an interface to configure as an Ethernet OAM
interface and enter interface configuration mode.
Enable Ethernet OAM on the interface
(Optional) Enter max-rate oampdus to set the
maximum rate (per second) to send OAM PDUs. The
range is 1 to 10 PDUs per second; the default is 10.
(Optional) Enter min-rate seconds to set the minimum
rate in seconds.The range is 1 to 10 seconds.
(Optional) Set the OAM client mode as active or
passive. The default is active.
(Optional) Enter timeout seconds to set the time after
which a device declares the OAM peer to be
nonoperational and resets its state machine. The range
is 2 to 30 seconds; the default is 5 seconds.
Return to privileged EXEC mode.
(Optional) Save your entries in the configuration file.
(Optional) Display the port states as reported by Ethernet
OAM.