Section 10 - Maintenance
power supply.
Result: The charger should operate and begin charging the batteries.
Result: If, simultaneously, the charger alarm sounds and the LEDs blink, correct the charger
connections at the fuse and battery. The charger will then operate correctly and begin
charging the batteries.
Note: For best results, use an extension cord of adequate size with a length no longer than 50 feet
(15 meters).
Note: If you have any further questions regarding the battery charger operation, please contact the
MEC Customer Service.
Electrical Wiring
Maintaining electrical wiring in good condition is essential to safe operation and good machine
performance. Failure to find and replace burnt, chafed, corroded or pinched wires could result in
unsafe operating conditions and may cause component damage.
ART_6091
WARNING
1. Inspect the following areas for burnt, chafed, corroded and loose wires:
Ground Control Panel
Hydraulic Power Unit Module Tray
Platform Controls
2. Turn the key switch to ground control and pull the red Emergency Stop button out to the On
position (pulled out) at both the ground and platform controls
3. Raise the platform approximately 7.2 feet (2.2 meters) from the ground.
4. Lift the safety arm, move it to the center of the scissor arm and rotate up to a vertical position.
5. Lower the platform onto the safety arm.
ART_6091
WARNING
6. Inspect the center chassis area and scissor arms for burnt, chafed and pinched cables.
7. Inspect the following areas for burnt, chafed, corroded, pinched and loose wires:
Scissor Arms
ECU to Platform Controls
Power to Platform Wiring
8. Inspect for a liberal coating of dielectric grease in the following locations:
Between the ECU and platform controls
All wire harness connectors Level sensor
9. Raise the platform and return the safety arm to the stowed position.
10. Lower the platform to the stowed position and turn the machine off.
Page 18
ELECTROCUTION / BURN HAZARD. CONTACT WITH ELECTRICALLY
CHARGED CIRCUITS COULD RESULT IN DEATH OR SERIOUS INJURY.
REMOVE ALL RINGS, WATCHES AND OTHER JEWELRY.
CRUSHING HAZARD. KEEP HANDS CLEAR OF THE SAFETY ARM WHEN
LOWERING THE PLATFORM.