3Com 3032 Configuration Manual page 398

3com 3032: user guide
Hide thumbs Also See for 3032:
Table of Contents

Advertisement

394
C
25: C
HAPTER
ONFIGURING
DLS
W
By default, the modulo value of SDLC is 8.
d Configure Maximum Receivable Frame Length N1 of SDLC
Maximum frame length of SDLC refers to byte number of maximum
transmissible and receivable message, not including parity bit and stop bit.
Please process the following configurations in the synchronous interface view.
Table 457 Configure maximum receivable frame length of SDLC
Operation
Configure Maximum Receivable Frame Length of SDLC
Restore the default value of maximum receivable frame
length of SDLC
By default, the maximum receivable frame length of SDLC is 265 bytes.
Generally, the length is 265 for some PU2.0 equipment and 521 for IBM
AS/400. We often need to configure our equipment to be of the same values
as the connected SDLC equipment.
e Configure Retransmission Number N2 of SDLC
The retransmission number N2 of SDLC refers to the retransmission number
before receiving no acknowledgement packet sent by the other part.
Please process the following configurations in the synchronous interface view.
Table 458 Configure retransmission number of SDLC
Operation
Configure retransmission number of SDLC
Restore the default value of the retransmission
number of SDLC
By default, the retransmission number of SDLC is 20.
f Configure Poll Time Interval of SDLC
Poll time interval of SDLC refers to wait time interval between two SDLC nodes
polled by SDLC primary station.
Please process the following configurations in the synchronous interface view.
Table 459 Configure poll time interval of SDLC
Operation
Configure poll time interval of SDLC
Restore the default value of poll time interval of SDLC undo sdlc timer poll
By default, the poll time interval of SDLC is 100 ms.
g Configure SAP address for transforming SDLC to LLC2
When transforming SDLC message to LLC2 message, it needs both SAP and
MAC addresses. This command is used to specify SAP address used when
transforming LLC2 for a SDLC byte.
Generally, the SAP address used by SNA protocol is 0x04, 0x08 or 0x0C.
Please process the following configurations in the synchronous interface view.
Command
sdlc max-pdu n
undo sdlc max-pdu
Command
sdlc max-transmission
retries
undo sdlc max-transmission
Command
sdlc timer poll mseconds

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

303430333035304030413036 ... Show all

Table of Contents