3Com 3032 Configuration Manual page 135

3com 3032: user guide
Hide thumbs Also See for 3032:
Table of Contents

Advertisement

Configure CE1/PRI
Interface
1 Enter the view for a specified interface
2 Set the interface operating mode
When the interface is used as a CE1 interface, all the timeslots except timeslot
0 can be divided into multiple channel sets at will, and each group can be used
as an interface upon timeslot binding. Its logic feature is the same as that of a
synchronous serial interface. It supports the data link layer protocols, such as
PPP, Frame Relay, LAPB and X.25, and the network protocols such as IP and IPX.
When the interface is used as a PRI interface, timeslot 16 will be used as a D
channel to transmit signaling. Therefore, only a group of timeslots except the
timeslots 0 and 16 can be chosen as the B channels. These timeslots can be
bound together with timeslot 16 to form a pri set to be used as an interface.
The logic feature of this interface will be the same as that of an ISDN PRI
interface. It will support the data link layer protocol PPP and network protocols,
such as IP and IPX, and can be configured with parameters such as BDR
(Dial-on-Demand Routing).
CE1/PRI interface configuration includes:
Enter the view for a specified interface
Set the interface operating mode
Bind the interface to be channel sets
Bind the interface to be a pri set
Set the line code format
Set line clock
Set frame format
Enable/disable internal loopback/external loopback
In system view, use the following command to enter the view of a specified
CE1/PRI interface.
Table 125 Enter the view of a specified interface
Operation
Enter the view of CE1/PRI interface
CE1/PRI interface has two operating modes: E1 operating mode and CE1/PRI
operating mode
Perform the following configurations in CE1/PRI interface view.
Table 126 Set the operating mode of CE1/PRI interface
Operation
Set the CE1/PRI interface to operate in E1 mode
Set the CE1/PRI interface to operate in CE1/PRI mode
By default, the CE1/PRI interface operates in CE1/PRI operating mode.
After enabling the CE1/PRI interface to operate in E1 mode using the
command, the system will automatically create a serial interface numbered
number:
. This interface owns the same logic feature as that of a synchronous
0
serial interface, and can be treated as a synchronous serial interface for further
configurations.
Perform the following configuration in all views.
CE1/PRI Interface
Command
controller e1 number
Command
using e1
using ce1
using e1
serial