X6#
20
= Pulse time in
ms counts.
X6(
= The number of seconds before timeout on IP connections
X7&
= Prefix (subnet mask bits)
X8#
= Enabled/disabled status
X9(
= Host domain name
X56&
= Firmware query
X57^
= NIC (Network Interface Card) number (
X57&
= Prefix (subnet mask bits).
X58!
= Text, 1 to 64 characters
X59#
= DHCP modes
X59$
= IPv6 (normal) IP address (
X59%
= Single "primary" IPv6 IP address (see
X71#
= Power receptacle name (17 characters).
X71$
= Aggregate current value, precise to one decimal place (
X71%
= Model name
X71^
= Model description
X71&
= Product part number
IPL EXP Power Series • Modes of Operation, SIS Control and Configuration
If parameter is missing or =
25
500
=
ms. Maximum =
1
Minimum =
, maximum =
30
default =
= 300 seconds).
If no data is received during the timeout period, the Ethernet
connection is closed. Each step is 10 seconds. Applicable to
Ethernet only.
255.255.0.0
Subnet
Default subnet mask bits response for
/16
IPv4) =
.
0
1
= disabled,
= enabled
* = Firmware and build number:
0
= Detailed version information:
(the series of responses from
1
= Firmware version: <
(file system version, which represents the entire system)
2
= Final stage bootloader (Uboot) version: <
3
= Factory base code version: [<
zzzz-bxxx)>*<kernel version (x.yyLX) – description –
date loaded
>]
4
= Updated firmware version: [<
zzzz-bxxx)>* <kernel version (x.yyLX) – description –
date loaded
>]
1-3
). For the IPL EXP, the NIC number is 1. If a NIC number is
not applicable to the product, the unit returns an E13 error code.
Subnet 255.255.0.0 is represented as a prefix value by /16.
This can be comprised of all human-readable characters except the
pipe (|) character. It cannot be a single space.
0
= static (and link-local) addresses
1
= automatic (DHCPv6, SLAAC, and link-local) addresses (default)
2
= Use DHCPv6 (and link-local) addresses.
3
= Use SLAAC (and link-local) addresses. Use DHCPv6 for DNS
information.
4
= Use SLAAC (and link-local) addresses.
5
= Use only the link-local address.
xxxx:xxxx:xxxx:xxxx
xxxx:xxxx:xxxx:xxxx
:
x
0-f
= hex digit (
). Leading zeros in each of 8 fields are optional in
setting values and are suppressed in returned values. Unlike IPv4,
there is no default for static.
X59$
) returned from CISG6 query based upon the following
order of priority if multiple addresses exist:
1. Static address (if mode is static)
2. DHCPv6 address
3. Permanent SLAAC address
4. Temporary SLAAC address
5. Temporary, deprecated SLAAC address
6. Link-local address
7. Static address (if mode is not static)
The default name is "AC Power Output
DC Power Output X!
"
For example: IPL EXP PDU4H or IPL EXP PDU8L
"Control System Power Expansion Interface"
x
60-1956-0
or 60-1928-01
0
, then pulse length defaults to
65535
1330
=
seconds.
65000
,
is represented as a prefix value by
E CISG
x.yy.zzzz
<2Q> - <3Q> - < 4Q>
2Q-3Q-4Q
commands)
currently running version (x.yy)
x.yy
factory base code (x.yy.
updated code version (x.yy.
).
X!
" (for IPL EXP PDU4H) or
" (for IPL EXP PDU8L).
0.1
A)
/16
.
command (on
>
>
29
Need help?
Do you have a question about the IPL EXP Series and is the answer not in the manual?
Questions and answers