Command Symbol Definitions
]
•
} or
E
|
*
X!
X@
X%
X1!
X1@
X1#
X1$
X1%
X1^
X1*
X1(
X2@
X3#
X3^
X4!
X4(
=
Carriage return/line feed (hex 0D 0A)
=
space character
=
Carriage return (no line feed
|
W
w
or
or
=
Escape key
=
Pipe (vertical bar) character
=
Asterisk character (which is a command character, not a variable)
= Power output number
= Contact closure port number
(Manual Control port number)
= On or Off status
= Relay port number
= Unit name
= Local date and time format
= IP address, subnet,
gateway address
= Open/closed status
= Power-up delay period between ports in
= Hardware (MAC) address
= Subnet mask
= Verbose response mode
= Password
= Port number
= Reading password
= Default unit name
IPL EXP Power Series • Modes of Operation, SIS Control and Configuration
) (for URL-encoded commands, use the pipe character,
, hex 0D
instead)
0
= all outputs
1-4
= outputs 1-4 (IPL EXP PDU4H)
1-8
= outputs 1-8 (IPL EXP PDU8L)
1-4
0
1
= Off,
= On
1
A text string up to 63 characters drawn from
the alphabet (A-Z), digits (0-9), minus sign or hyphen (-).
No blank or space characters are permitted as part of a name.
No distinction is made between upper and lower case. The first
character must be an alpha character. The last character must not
be a minus sign or hyphen.
MM/DD/YY-HH:MM:SS
For set commands:
10:54:00
.
day of week, date month year
For read commands: (
HH:MM:SS
Wed, 22 Jan 2022 10:54:00
). Example:
xxx.xxx.xxx.xxx
(Leading zeros are optional.)
0
= open
1
= closed
0.1
second increments, 1-255 (max.).
10
Default =
(1 second).
00-05-A6-xx-xx-xx
xxx.xxx.xxx.xxx
Leading zeros in each of 4 fields are optional in setting values, and
are suppressed in returned values.
255.255.0.0
Default =
.
0
= Clear/none (default)
1
= Verbose mode is on (enabled)
2
= Verbose mode is off, tagged responses are sent for queries
3
= Verbose mode is on (enabled) and tagged responses are
enabled and sent for queries
If tagged responses is enabled, all read commands return the
constant string + the data, like setting the value does.
E CN
(Example command:
1
128
A string of from
to
human-readable ASCII characters (except
|
the pipe character
). The password cannot be a single space, and
it cannot be empty (nothing). The initial (factory-set) password is
the serial number of the unit. The default after a reset is
Passwords are case-sensitive.
Response is 5 digits with leading zeros, for example
00023
.
Instead of the actual password, the unit responds with four
asterisks (****) if a password exists, and it responds with an empty
field (nothing) if no password exists.
Default unit name is a combination of the modelname and last three
pairs of the MAC address (such as
01/12/22-
. Example:
Ipn
X1@]
} Response:
•
00000
IPL-EXP-PDU4H-00-02-3D
|
,
.
).
extron
.
or
).
28