Operation and correct use
8.2.1

Remove condensation from the cabinet

To remove condensation inside the charger, carry out the following procedure:
• Perform the Total de-energization procedure. Refer to section
• Open the front and right doors. Refer to section
• Move the selector on the two main DC breakers (35) from the
Auto to the Manual position (A).
• Push OFF (B) to open the two main DC breakers (35).
• Close the doors. Refer to section
• Set the upstream breaker to ON position to provide power to the EVSE.
• Wait four hours at least.
NOTE
The internal heater of the cabinet heats the inside of the cabinet and lets the condensation
evaporate.
When the procedure is completed, perform the following operations to set the charger to normal operating
conditions:
• Perform the Total de-energization procedure. Refer to section
• Open the front and right doors. Refer to section
• Push ON (C) to close the two main DC breakers (35).
• Move the selector on the two main DC breakers (35) from the
Manual to the Auto position (D).
• Close the doors. Refer to section
"5. Access to the internal parts"
"5. Access to the internal parts"
"5. Access to the internal parts"
"5. Access to the internal parts"
"9.3. Total de-energization of the EVSE"
Push OFF
"9.3. Total de-energization of the EVSE"
Push OFF
63
A
Auto
Man
B
Push ON
D
Auto
Man
C
Push ON

Advertisement

Table of Contents
loading

This manual is also suitable for:

Terra 124 ulTerra 184 ul