Step 2.
Remove the XCC management module.
a.
Disconnect the XCC management module cable from the OCP cage.
b.
Remove the screws from the front of the XCC management module.
c.
Push the XCC management module from the inside out.
Figure 134. Removal of the XCC management module
After this task is completed
1. Install a replacement unit (see
2. If you are instructed to return the component or optional device, follow all packaging instructions, and
use any packaging materials for shipping that are supplied to you.
Install an XCC management module
Follow instructions in this section to install an XCC management module.
About this task
To avoid potential danger, make sure to read and follow the safety information.
Attention:
• Read
"Installation Guidelines" on page 43
you work safely.
• Touch the static-protective package that contains the component to any unpainted metal surface on the
node and chassis; then, take the component out of the package and place it on a static-protective
surface.
Firmware and driver download: You might need to update the firmware or driver after replacing a
component.
• Go to
https://datacentersupport.lenovo.com/products/servers/thinksystem/sd550v3/7dd2/downloads/driver-
to see the latest firmware and driver updates for your server.
list
• Go to
"Update the firmware" on page 231
Procedure
"Install an XCC management module" on page
and
"Safety inspection checklist" on page 44
for more information on firmware updating tools.
207).
.
Chapter 5
Hardware replacement procedures
to make sure that
207