9.6

Cleaning

9.6.1

Machine

1. Bring the processing table to a position where you find it easy to clean the surface with window cleaning agents and
paper towels.
2. Switch off the unit and disconnect it from the mains.
3. Open the acrylic lid and the front lid.
4. Thoroughly remove all loose dirt and deposits from the inside of the machine (e.g. with a brush or vacuum cleaner).
To do this, it is necessary to remove the table and the table tray.
5. Clean the air baffle and suction slots of the suction box in the interior with a dry or slightly damp cotton cloth or a
brush.
6. Clean the laser tube cover and ventilation slots on the back of the machine with a dry or slightly damp cotton cloth.
7. Clean the safety lid with a dry or slightly damp cotton cloth. Do not use paper towels as these could scratch the
acrylic.
9.6.2

Optics in general

Trotec Laser GmbH recommends to use the cleaning set enclosed. Alternatively, use high-quality cotton swabs together
with the provided cleaning liquid.
Notice
The following cleaning products are available as accessory parts:
Lens cleaning cloth
Lens cleaning liquid
Maintenance