Technical Data
3.5

Exhaust system requirements

Danger
Danger of emission of toxic gases, vapors or dust.
During laser operation, toxic aerosols may be produced.
The laser system may be operated only with properly installed and operating exhaust system.
Check with the material manufacturer for its toxic effect.
Caution
The laser may only be operated with properly installed and operating exhaust system. Damage to the
system, caused by the use of not any exhaust system or improper extraction equipment, will not be
covered by any liability.
The requirements for the exhaust system and recommended Trotec exhaust systems for standard applications depend
on the processing table installed in the machine. We recommend consulting with a qualified Trotec technician.
RECOMMENDED EXHAUST SYSTEMS:
Exhaust system
Atmos Pure 300
Atmos Pure 600
Atmos Duo Plus
Vent Set 400
Vent Set 500
Notice
Connection has to be carried out by our Technical Support.
Observe instructions for operation and maintenance according to the operating manual of the exhaust
system.
TECHNICAL DATA FOR THE EXHAUST SYSTEMS:
Exhaust system
Hose connector ø [mm]
(internal diameter)
Atmos Pure 300
(3x) 80
Atmos Pure 600
(3x) 80
Atmos Duo Plus
70 / 70 / 45
Vent Set 400
100
30
Speedy 360
✓ (without vacuum table)
Volume flow rate [m³/h]
352 (115V)
378 (230V)
(2x) 378
(2x) 320
max. 1000
Pressure [Pa]
6500 (115V)
8000 (230V)
8000
8500 (230V)
max. 3800