11 WATER CONNECTION FITTINGS
Key to abbreviations used for water connections.
CODE
FILLING/DISCHARGE
cw
dw
d
cd
11.1
WATER INTAKE
11.1.1 WATER INTAKE CONNECTION
The appliance has two intake hoses, for mains and demineralised water.
The hoses are designed to be connected to taps with 3/4'' gas threaded attachment.
Use the filter provided, "A" in the illustration, when connecting the end of the intake hose.
MODELS
Tethys D60
Tethys T60
Tethys T45
11.1.2 WATER SUPPLY TAP POSITION
Water supply taps must be positioned close to the appliance, in a position accessible to the user. With reference to
the diagram below, the recommended measurements are:
There are no particular height requirements for the position of the water supply taps, but bear in mind that the hoses
supplied are about 2 metres long.
fig. 45 – Diagram. The water supply connections may be on the right or left of the appliance, always considering the maximum distance "I".
Note to prevent the risk of clogging or damage: if the water pipe is new or has been unused for a long time, before
connecting the water supply make sure that the water is clear and free of impurities.
User Manual
INTAKE
cold water hose - cw (cold water)
INTAKE
pressurised demineralised water hose - dw (demi water)
DRAIN
appliance drain hose - d (drain)
DRAIN
steam condenser drain hose - cd (condenser drain)
fig. 44 – Fit the filters provided when connecting the intake hose.
NUMBER
CONNECTIONS
2
Tethys D60 - Tethys T60 - Tethys T45
WATER TYPE
cw
1
I <50 cm
HC < 100 cm
CONNECTION TYPE
dw
1
Page 72 - 77
hw
---