NOTE - CYCLE COMPLETION TIMES
The completion times shown on the display are guideline: they may vary due to factors such as
the intake water temperature and pressure.
At the end of each program, a resin regeneration phase may be automatically tripped, followed by
resin washing, to ensure that the integral softener operates correctly. These procedures do not
take place at every cycle but are triggered as needed, depending on the intake water hardness and
the amount of water used.
The procedures are not included in the theoretical cycle time shown initially on the display.
In order for the real times to be close to the theoretical stated times, the appliance parameters
must be set appropriately, so that the time passed is calculated on the basis of the electrical
connection as made.
5.6

PROGRAMS INSTALLED

See enclosed document: "Tethys T45 Program Table", "Tethys D60-Tethys T60 Program Table". The data provided
may be subject to modification. The drying phase is only present in the Tethys D60.
CUSTOM PROGRAMS
In addition to the standard programs, which cannot be modified by the user, modifiable programs
are also available.
The Custom programs are programs which can be modified to meet specific requirements.
Programs can only be modified using the TRACELOG software; contact your local dealer for
information concerning the use and installation of the program.
MAINS WATER - DEMINERALISED WATER in PROGRAMS
The enclosed table indicates when a specific phase takes in cold water and when demineralised
water.
If demineralised water is deselected by means of the appliance setup parameters, the appliance
will always take in cold water.
Whenever possible, connection to demineralised water is recommended, for better final rinsing
results and to avoid the formation of limescale.
5.6.1

RESINS - SOFTENER, REGENERATION AND WASHING PHASE

The softener incorporated in the device removes calcium compounds from the intake water to reduce its hardness.
The softener comprises a container of ion exchanger resins, which must be regenerated regularly.
The appliance decides when a resin regeneration and washing cycle is needed depending on the hardness set and the
quantity of water treated.
User Manual
fig. 11 – Example of a Display screen. Program 5 selected
The program includes a drying phase – Drying LED on.
The program includes a thermal disinfection phase– "Td" LED on.