WARNING
The drain must comply with international regulations: our company accepts no liability for
pollution caused by improper use of the appliance.
General guidelines for installing the drain
The use of a drain with syphon trap is recommended. During installation, the following precautions should be
complied with:
Since the drain water temperature is 95°C, the end of the drain hose must be permanently connected to the hose
connector, using the ties provided.
There must be no sharp bends in the drain hose which might cause restrictions.
The difference in height between the end of the drain hose and the surface on which the appliance is installed
must comply with the stated specifications.
The end of the hose must never be submerged in water.
The inside diameter of the drain pipe to which the hose is connected must be at least 40 mm.
A drain pipe 50 mm in diameter is recommended.
No extensions must be added to the drain hose supplied with the appliance. Any extensions might cause problems
of flow-back into the chamber.
User Manual
fig. 48 – Adapter with connector for 1/2" hose.
Tethys D60 - Tethys T60 - Tethys T45
Page 75 - 77