Honda Shadow TA200 2001 Manual page 89

Table of Contents

Advertisement

FUEL SYSTEM
Connect a pressure pump to the 8 mm (0.31 in) 1.0. hose that
goes to the evaporative emission canister. While applying the
specified vacuum to the EVAP purge control valve hose that
goes to the carburetor body, pump air through the evapora-
tive emimssion canister hose. Air should flow through the
EVAP purge control valve and out the hose that goes to the
carburetor body.
Replace the EVAP purge control valve if air does not liow out.
CAUTION:
To prevent damage to the EVAP purge control valve, do not
use
high
air pressure sources, Use a hand operated air pump
only.
Remove the pumps, i n stall the EVAP purge contorol valve on
its mount, route and reconnect the hose according to the
routing l a bel.
CANISTER
REMOVAL/INSTALLATION
Remove the fuel tank (page 2-5)
Disconnect the tubes from the canister.
Remove the air cleaner housing (page 5-5).
Pull out the canister from the air cleaner.
Remove the canister mount rubber from the canister.
Installation i s in the reverse order ol removal.