The Seat Inclines During The Ride; Calibration - Handicare Freecurve Technical Manual

Hide thumbs Also See for Freecurve:
Table of Contents

Advertisement

13
|

The seat inclines during the ride

The seat inclines in program mode
Incorrect datacard
The calibration has not be done on the calibration point
The linking of the remotes have not be done on the calibration point
Wire break between K5-1/2/3/4 and the encoder
Wire break between K2-1/2/3/4 and the encoder
The traction motor encoder is faulty
The seat leveling motor is faulty
Wire break between K5-5 and K5-6 (standard between 40 - 70 Ω)
Wire beak between K5-7 and K5-8 (standard between 0 - 2 Ω)
Earth short at K5-1, K5-2
Low/weak batteries
Poor rail installation that has not been set to the correct angles on the drawing
14
|

Calibration

The lift continues to function in the user mode, were it should operate in the traction mode
Wire break between K4-1/2/3 and the calibration switch (CS)
Earth short at K4-1, K4-2, K4-3