13
|
The seat inclines during the ride
The seat inclines in program mode
•
Incorrect datacard
•
The calibration has not be done on the calibration point
•
The linking of the remotes have not be done on the calibration point
•
Wire break between K5-1/2/3/4 and the encoder
•
Wire break between K2-1/2/3/4 and the encoder
•
The traction motor encoder is faulty
•
The seat leveling motor is faulty
•
Wire break between K5-5 and K5-6 (standard between 40 - 70 Ω)
•
Wire beak between K5-7 and K5-8 (standard between 0 - 2 Ω)
•
Earth short at K5-1, K5-2
•
Low/weak batteries
•
Poor rail installation that has not been set to the correct angles on the drawing
14
|
Calibration
The lift continues to function in the user mode, were it should operate in the traction mode
•
Wire break between K4-1/2/3 and the calibration switch (CS)
•
Earth short at K4-1, K4-2, K4-3
Technical manual
77