Trigger Sequencer mode

With this mode, the Sequencer Trigger "pattern" is predetermined by the user. The user defines up to
128 different "indexes." The items indicated in the above index can be configured for each index. The
operation of this mode is controlled using the following commands.
Note: In Trigger Sequencer Mode, when set SequencerMode to On, FrameStart (TriggerMode)
is forced to be On. When SequencerMode is returned to Off, FrrameStart(TriggerMode) will
remain On.
Sample TriggerSequencer mode operation
User-defined Indexes (up to 128)
1. Specify "1" in SequencerSetStart, and start TriggerSequencer mode with index 1.
2. Capture a 2-frame image with the first and second triggers.
3. For the next index, configure index 3 specified in SequencerSetNext, and capture an image with the
number of frames (number of triggers) specified in SequencerFrameNumber. Proceed to sequence
from index 4 to index 2 to index 1.
Note: In addition to repeating multiple conditions as in the example above, you can also specify 0
to indicate the end of TriggerSequencer mode in [SequencerSetNext] of index 2, and specify the
number of repetitions in [SequencerRepetition].